(viii) List of registers (3rd control settings)

Register

Function name

Function code

R/W

Monitoring and setting items Data resolution

Register

No.

 

 

 

 

No.

3103h

Acceleration (1) time setting, 3rd

F302 (high)

R/W

1 to 360000

0.01 [sec.]

3104h

motor

F302 (low)

R/W

3105h

Deceleration (1) time setting, 3rd

F303 (high)

R/W

1 to 360000

0.01 [sec.]

3106h

motor

F303 (low)

R/W

3107h to

(Reserved)

-

-

Inaccessible

-

3202h

 

 

 

 

 

(ix) List of registers (3rd control setting)

Register

Function name

Function code

R/W

Monitoring and setting items Data resolution

Register

No.

No.

 

 

 

 

3203h

Base frequency setting, 3rd

A303

R/W

30 to "maximum frequency, 3rd motor"

1 [Hz]

motor

 

 

 

 

 

3204h

Maximum frequency setting, 3rd

A304

R/W

30 to 400

1 [Hz]

motor

 

 

 

 

 

3205h to

(Reserved)

-

-

Inaccessible

-

3215h

 

 

 

 

 

3216h

Multispeed frequency setting, 3rd

A320 (high)

R/W

0 or "start frequency" to "maximum frequency, 3rd

0.01 [Hz]

3217h

motor

A320 (low)

R/W

motor"

 

3218h to

(Reserved)

-

-

Inaccessible

-

323Bh

 

 

 

 

 

323Ch

Manual torque boost value, 3rd

A342

R/W

0 to 200

0.1 [%]

motor

 

 

 

 

 

323Dh

Manual torque boost frequency

A343

R/W

0 to 500

0.1 [%]

adjustment, 3rd motor

 

 

 

 

 

323Eh

V/F characteristic curve

A344

R/W

0 (VC), 1(VP)

-

selection, 3rd motor

 

 

 

 

 

323Fh to

(Reserved)

-

-

Inaccessible

-

326Ch

 

 

 

 

 

326Dh

Acceleration (2) time setting, 3rd

A392 (high)

R/W

1 to 360000

0.01 [sec.]

326Eh

motor

A392 (low)

R/W

 

 

326Fh

Deceleration (2) time setting, 3rd

A393 (high)

R/W

1 to 360000

0.01 [sec.]

3270h

motor

A393 (low)

R/W

 

 

3271h to

(Reserved)

-

-

Inaccessible

-

330B

 

 

 

 

 

 

Electronic thermal setting

 

 

 

 

330Ch

(calculated within the inverter

b312

R/W

200 to 1000

0.1 [%]

 

from current output), 3rd motor

 

 

 

 

330Dh

Electronic thermal characteristic,

b313

R/W

0 (reduced-torque characteristic), 1

-

3rd motor

(constant-torque characteristic), 2 (free setting)

330Eh to

(Reserved)

-

-

Inaccessible

-

3506h

 

 

 

 

 

3507h

Motor stabilization constant, 3rd

H306

R/W

0 to 255

1

motor

 

 

 

 

 

3508h to

(Reserved)

-

-

Inaccessible

-

4 - 162

Page 220
Image 220