b092: Cooling fan control
d022: Life-check monitoring

Chapter 4 Explanation of Functions

4.2.69 Cooling-fan speed drop signal (WAF)

The inverter outputs the cooling-fan speed drop (WAF) signal when it detects that the rotation speed of its internal cooling fan has fallen to 75% or less of the full speed.

If "01" has been selected for the cooling fan control (b092), the inverter will not output the WAF signal, even when the cooling fan stops.

If the WAF signal is output, check the cooling-fan cover for clogging.

You can monitor the state of the WAF signal by using the life-check monitoring function (d022).

Item

Function code

Data

Description

Terminal function

C021 to C025

40

WAF: Cooling-fan speed

Alarm relay terminal function

C026

drop signal

 

4.2.70 Starting contact signal (FR)

The inverter outputs the starting contact (FR) signal while it is receiving an operation command.

The FR signal is output, regardless of the setting of the run command source setting (A002).

If the forward operation (FW) and reverse operation (RV) commands are input at the same time, the inverter stops the motor operation.

Item

Function code

Data

Description

Terminal function

C021 to C025

41

FR: Starting contact

Alarm relay terminal function

C026

signal

 

Forward operation command

Reverse operation command

Starting contact signal (FR)

4.2.71 Heat sink overheat warning signal (OHF)

The inverter monitors the temperature of its internal heat sink, and outputs the heat sink overheat warning (OHF) signal when the temperature exceeds the heat sink overheat warning level (C064).

Related code

C021 to C025: Terminal [11] to [15] functions

C026: Alarm relay terminal function

C064: Heat sink overheat warning level

Item

Function code

Data or range of data

Description

Terminal function

C021 to C025

42

OHF: Heat sink overheat warning

Alarm relay terminal function

C026

signal

 

 

 

 

Setting of the threshold

Heat sink overheat warning level

C064

0. to 200. ()

temperature at which to output the

 

 

 

heat sink overheat warning signal

4 - 68