Chapter 4 Explanation of Functions

(2) Automatic torque boost

When automatic torque boost (data "01") is selected by the torque boost selection (A041/A241), the inverter automatically adjusts the output frequency and voltage according to the load on the motor. (During actual operation, the automatic torque boost is usually combined with the manual torque boost.) When you select the automatic torque boost, adjust the settings of the motor capacity selection (H003/H203) and motor pole selection (H004/H204) according to the motor to be driven.

If the inverter trips due to overcurrent during motor deceleration, set the AVR function select (A081) to always enable the AVR function (data "00").

If you cannot obtain the desired operation characteristic by using the automatic torque boost, make the following adjustments:

Symptom

 

Adjustment method

Adjustment item

 

(1)

Increase the voltage setting for manual torque boost

A042/A242

Motor torque is insufficient at low

step by step.

 

(2)

Increase the slippage compensation gain for

 

speed.

A047/A247

automatic torque boost step by step.

(The motor does not rotate at low

 

(3)

Increase the voltage compensation gain for

 

speed.)

A046/A246

automatic torque boost step by step.

 

 

 

(4)

Reduce the carrier frequency setting.

b083

The motor speed falls when a load

Increase the slippage compensation gain for the

A047/A247

is applied to the motor.

automatic torque boost step by step.

 

The motor speed increases when a

Reduce the slippage compensation gain for the

A047/A247

load is applied to the motor.

automatic torque boost step by step.

 

 

(1)

Reduce the voltage compensation gain for the

A046/A246

 

automatic torque boost step by step.

The inverter trips due to overcurrent

 

(2)

Reduce the slippage compensation gain for the

A047/A247

when a load is applied to the motor.

automatic torque boost step by step.

 

 

(3)

Reduce the voltage setting for the manual torque

A042/A242

 

boost step by step.

 

 

This function cannot be selection for 3rd moter setting.

Manual torque boost valid.