Hitachi SJ700-2 Explanation of main circuit terminals, Explanation of control circuit terminals

Models: SJ700-2

1 274
Download 274 pages 15.86 Kb
Page 29
Image 29

 

 

 

 

 

 

Chapter 2 Installation and Wiring

 

 

 

 

 

 

 

 

 

 

 

(1) Explanation of main circuit terminals

 

 

 

 

 

 

 

 

 

 

 

Symbol

Terminal name

Description

 

 

 

R, S, T

Main power input

Connect to the AC power supply.

 

 

 

(L1, L2, L3)

Leave these terminals unconnected when using a regenerative converter (HS900 series).

 

 

 

U, V, W

Inverter output

Connect a 3-phase motor.

 

 

 

(T1, T2, T3)

 

 

 

PD, P

DC reactor connection

Remove the jumper from terminals PD and P, and connect the optional power factor reactor

 

 

(+1, +)

 

(DCL).

 

 

 

P, RB

External braking

Connect the optional external braking resistor.

 

 

 

(+, RB)

resistor connection

(The RB terminal is provided on models with 22 kW or less capacity.)

 

 

 

P, N

Regenerative braking

Connect the optional regenerative braking unit (BRD).

 

 

(+, -)

unit connection

 

 

 

 

 

 

 

G

Inverter ground

Connect to ground for grounding the inverter chassis by type-D grounding (for 200 V class

 

 

 

 

 

 

models) or type-C grounding (for 400 V class models).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) Explanation of control circuit terminals

Symbol

 

Power supply

 

L

 

 

 

 

 

 

 

H

 

 

setting input

 

O

 

 

 

O2

 

 

Frequency

 

Analog

 

 

OI

 

 

 

 

 

 

Monitor output

 

AM

 

 

 

AMI

 

 

 

 

 

 

output

 

 

 

 

Monitor

 

FM

 

 

 

 

 

 

supply

 

P24

 

 

 

 

(contact)

 

Power

 

CM1

 

 

 

 

Digital

 

Operation

command

FW

 

 

 

 

 

input

 

logic

 

1

Contact

 

andselection

switching

2

 

 

 

 

 

 

 

 

3

 

 

 

 

4

 

 

 

 

5

 

 

Function

 

6

 

 

 

7

 

 

 

 

8

 

 

 

 

 

Terminal name

Description

Electric property

 

Analog power

This common terminal supplies power to frequency command terminals (O,

 

 

 

 

supply

O2, and OI) and analog output terminals (AM and AMI). Do not ground this

 

 

 

 

(common)

terminal.

 

 

 

 

Frequency

 

Allowable

load current:

20

setting power

This terminal supplies 10 VDC power to the O, O2, OI terminals.

mA or less

 

 

 

supply

 

 

 

 

 

 

 

 

 

Frequency

Input a voltage (0 to 10 VDC) as a frequency command. 10 V specifies the

Input impedance: 10kH

 

command

maximum frequency.

Allowable

input

voltages:

To specify the maximum frequency with a voltage of 10 V or less, set the

(voltage)

voltage using function "A014".

-0.3 to +12 VDC

 

 

 

 

 

 

 

Auxiliary

Input a voltage (0 to ±10 VDC) as a signal to be added to the frequency

Input impedance: 10kH

 

frequency

command input from the O or OI terminal. You can input an independent

 

command

frequency command from this terminal (O2 terminal) alone by changing the

Allowable input voltages:

(voltage)

setting.

0 to ±12 VDC

 

 

 

 

 

 

Frequency

Input a current (4 to 20 mA DC) as a frequency command. 20 mA specifies

Input impedance: 10kH

 

command

the maximum frequency.

Maximum

 

allowable

The OI signal is valid only when the AT signal is on. Assign the AT function

 

(current)

to an intelligent input terminal.

current: 24 mA

 

 

 

 

 

 

 

 

This terminal outputs one of the selected "0 to 10 VDC voltage output"

 

 

 

 

Analog monitor

monitoring items. The monitoring items available for selection include

Maximum

 

allowable

(voltage)

output frequency, output current, output torque (signed or unsigned),

current: 2 mA

 

 

output voltage, input power, electronic thermal overload, LAD frequency,

 

 

 

motor temperature, heat sink temperature, and general output.

 

 

 

 

 

This terminal outputs one of the selected "4 to 20 mA DC current output"

 

 

 

 

Analog monitor

monitoring items. The monitoring items available for selection include

Allowable load impedance:

(current)

output frequency, output current, output torque (unsigned), output voltage,

250H or less

 

 

 

input power, electronic thermal overload, LAD frequency, motor

 

 

 

 

 

temperature, heat sink temperature, and general output.

 

 

 

 

 

This terminal outputs one of the selected "0 to 10 VDC voltage output

 

 

 

 

 

(PWM output mode)" monitoring items. The monitoring items available for

 

 

 

 

 

selection include output frequency, output current, output torque

Maximum

 

allowable

Digital monitor

(unsigned), output voltage, input power, electronic thermal overload, LAD

current: 1.2 mA

 

 

(voltage)

frequency, motor temperature, heat sink temperature, general output,

Maximum

frequency:

3.6

 

digital output frequency, and digital current monitor.

kHz

 

 

 

 

For the items "digital output frequency" and "digital current monitor," this

 

 

 

 

 

terminal outputs a digital pulse signal at 0/10 VDC with a duty ratio of 50%.

 

 

 

 

Interface power

This terminal supplies 24 VDC power for contact input signals.

Maximum

allowable output

supply

If the source logic is selected, this terminal is used as a common contact

current: 100 mA

 

 

 

input terminal.

 

 

 

 

Interface power

This common terminal supplies power to the interface power supply (P24),

 

 

 

 

thermistor input (TH), and digital monitor (FM) terminals. If the sink logic is

 

 

 

 

supply

selected, this terminal is used as a common contact input terminal. Do not

 

 

 

 

(common)

 

 

 

 

ground this terminal.

 

 

 

 

 

 

 

 

 

 

 

[Conditions for

turning

Forward rotation

Turn on this FW signal to start the forward rotation of the motor; turn it off to

contact input on]

 

 

command

stop forward rotation after deceleration.

Voltage across input

and

PLC: 18 VDC or more

 

 

 

 

 

 

Input impedance

between

 

Select eight of a total 60 functions, and assign these eight functions to

input and PLC: 4.7kH

 

 

terminals 1 to 8.

 

 

 

 

 

 

Maximum allowable voltage

Intelligent input

Note:

across input and PLC: 27

 

If the emergency stop function is used, terminals 1 and 3 are used

VDC

 

 

 

 

exclusively for the function. For details, see Item (3), "Emergency stop

 

 

 

 

 

function" (on page 2-8).

Load current with 27 VDC

 

 

power: about 5.6 mA

 

2 - 7

Page 29
Image 29
Hitachi SJ700-2 instruction manual Explanation of main circuit terminals, Explanation of control circuit terminals