Chapter 8 List of Data Settings

 

 

 

 

 

Default

 

Setting

Change

 

 

 

 

 

 

 

during

during

 

 

Code

Function name

Monitored data or setting

 

 

 

operation

operation

Page

 

 

 

 

_FF

_FEF

_FUF

(allowed

(allowed

 

 

 

 

 

or not)

or not)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C001

Terminal [1] function (*2)

01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting), 03 (CF2: Multispeed 2

 

18

 

¯

{

 

 

setting), 04 (CF3: Multispeed 3 setting), 05 (CF4: Multispeed 4 setting), 06 (JG:

 

(*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

Jogging), 07 (DB: external DC braking), 08 (SET: Set 2nd motor data), 09 (2CH:

 

 

 

 

 

 

 

C002

Terminal [2] function

 

16

 

¯

{

 

 

2-stage acceleration/deceleration), 11 (FRS: free-run stop), 12 (EXT: external trip),

 

 

 

 

C003

Terminal [3] function (*2)

13 (USP: unattended start protection), 14: (CS: commercial power source enable),

 

06

 

¯

{

 

 

15 (SFT: software lock), 16 (AT: analog input voltage/current select), 17 (SET3: 3rd

 

(*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

motor control), 18 (RS: reset), 20 (STA: starting by 3-wire input), 21 (STP: stopping

 

 

 

 

 

 

 

C004

Terminal [4] function

 

11

 

¯

{

 

 

by 3-wire input), 22 (F/R: forward/reverse switching by 3-wire input), 23 (PID: PID

 

 

 

 

C005

Terminal [5] function

 

09

 

 

 

 

 

disable), 24 (PIDC: PID reset), 26 (CAS: control gain setting), 27 (UP: remote

 

 

¯

{

 

 

C006

Terminal [6] function

control UP function), 28 (DWN: remote control DOWN function), 29 (DWN: remote

03

03

13

¯

{

 

 

control data clearing), 31 (OPE: forcible operation), 32 (SF1: multispeed bit 1), 33

 

 

C007

Terminal [7] function

 

02

 

¯

{

 

 

(SF2: multispeed bit 2), 34 (SF3: multispeed bit 3), 35 (SF4: multispeed bit 4), 36

 

 

 

 

 

 

(SF5: multispeed bit 5), 37 (SF6: multispeed bit 6), 38 (SF7: multispeed bit 7), 39

 

 

 

 

 

 

 

 

 

(OLR: overload restriction selection), 40 (TL: torque limit enable), 41 (TRQ1: torque

 

 

 

 

 

 

 

 

 

limit selection bit 1), 42 (TRQ2: torque limit selection bit 2), 43 (PPI: P/PI mode

 

 

 

 

 

4-46

 

 

 

selection), 44 (BOK: braking confirmation), 45 (ORT: orientation), 46 (LAC: LAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

terminals

 

 

cancellation), 47 (PCLR: clearance of position deviation), 48 (STAT: pulse train

 

 

 

 

 

 

 

 

position command input enable), 50 (ADD: trigger for frequency addition [A145]), 51

 

 

 

 

 

 

 

 

 

(F-TM: forcible-terminal operation), 52 (ATR: permission of torque command input),

 

 

 

 

 

 

 

 

 

53 (KHC: cumulative power clearance), 54 (SON: servo-on), 55 (FOC: forcing), 56

 

 

 

 

 

 

input

C008

Terminal [8] function

(MI1: general-purpose input 1), 57 (MI2: general-purpose input 2), 58 (MI3:

 

01

 

¯

{

 

general-purpose input 3), 59 (MI4: general-purpose input 4), 60 (MI5:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intelligent

 

 

general-purpose input 5), 61 (MI6: general-purpose input 6), 62 (MI7:

 

 

 

 

 

 

 

 

general-purpose input 7), 63 (MI8: general-purpose input 8), 65 (AHD: analog

 

 

 

 

 

 

 

 

 

command holding), 66 (CP1: multistage position settings selection 1 ), 67 (CP2:

 

 

 

 

 

 

 

 

 

multistage position settings selection 2), 68 (CP3: multistage position settings

 

 

 

 

 

 

 

 

 

selection 3), 69 (ORL: Zero-return limit function), 70 (ORG: Zero-return trigger

 

 

 

 

 

 

 

 

 

function), 71 (FOT: forward drive stop), 72 (ROT: reverse drive stop), 73 (SPD:

 

 

 

 

 

 

 

 

 

speed / position switching), 74 (PCNT: pulse counter), 75 (PCC: pulse counter

 

 

 

 

 

 

 

 

 

clear), no (NO: no assignment)

 

 

 

 

 

 

 

C011

Terminal [1] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C012

Terminal [2] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C013

Terminal [3] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C014

Terminal [4] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C015

Terminal [5] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

4-47

 

C016

Terminal [6] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C017

Terminal [7] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C018

Terminal [8] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

 

C019

Terminal [FW] active state

00 (NO) / 01 (NC)

 

00

 

¯

{

 

*2 When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003", respectively. (You cannot arbitrarily write "64" to "C001".) If the SW1 signal is turned off and then turned on, "no" (no assignment) is set in parameter "C003".