Chapter 4 Explanation of Functions

Note 6: The table below lists the functions of the intelligent input terminals and corresponding hexadecimal data for 12 command. (For details, see the explanation of the intelligent input terminal functions.)

Data (hexadecimal)

Description

Data (hexadecimal)

Description

0000000000000001

-

0000000100000000

-

0000000000000002

AHD: analog command holding

0000000200000000

-

0000000000000004

CP1: multistage position settings

0000000400000000

-

0000000000000008

selection 1

0000000800000000

-

0000000000000010

CP2: multistage position settings

0000001000000000

-

0000000000000020

selection 2

0000002000000000

-

0000000000000040

CP3: multistage position settings

0000004000000000

-

0000000000000080

selection 3

0000008000000000

-

0000000000000100

ORL: Zero-return limit function

0000010000000000

-

0000000000000200

ORG: Zero-return trigger function

0000020000000000

-

0000000000000400

FOT: forward drive stop

0000040000000000

-

0000000000000800

ROT: reverse drive stop

0000080000000000

-

0000000000001000

SPD: speed / position switching

0000100000000000

-

0000000000002000

PCNT: pulse counter

0000200000000000

-

0000000000004000

PCC: pulse counter clear

0000400000000000

-

0000000000008000

-

0000800000000000

-

0000000000010000

-

0001000000000000

-

0000000000020000

-

0002000000000000

-

0000000000040000

-

0004000000000000

-

0000000000080000

-

0008000000000000

-

0000000000100000

-

0010000000000000

-

0000000000200000

-

0020000000000000

-

0000000000400000

-

0040000000000000

-

0000000000800000

-

0080000000000000

-

0000000001000000

-

0100000000000000

-

0000000002000000

-

0200000000000000

-

0000000004000000

-

0400000000000000

-

0000000008000000

-

0800000000000000

-

0000000010000000

-

1000000000000000

-

0000000020000000

-

2000000000000000

-

0000000040000000

-

4000000000000000

-

0000000080000000

-

8000000000000000

-

 

-

 

 

 

-

 

 

 

-

 

 

(Example) When activating the "forward rotation," "Multispeed 1 setting," and "Multispeed 2 setting" settings on the inverter with station No. 01, specify the following in the Data part: 0x0000000000000001 + 0x0000000000000004 + 0x0000000000000008 = 0x000000000000000D Consequently, the whole transmission frame is as follows:

(STX) 0102000000000000000D (BCC) (CR) - Response frame

Positive response: See Item (2)-(i) of this section.

Negative response: See Item (2)-(ii) of this section.

4 - 119