Chapter 4 Explanation of Functions

 

 

 

 

 

 

(v) List of registers (function modes)

 

 

 

Register

Function name

Function code

R/W

Monitoring and setting items

Data

No.

resolution

 

 

 

 

 

 

 

 

0 (keypad potentiometer), 1 (control circuit terminal

 

1201h

Frequency source setting

A001

R/W

block), 2 (digital operator), 3 (RS485), 4 (option 1), 5

-

(option 2), 6 (pulse train input), 7 (easy sequence), 10

 

 

 

 

(operation function result)

 

1202h

Run command source setting

A002

R/W

1 (control circuit terminal block), 2 (digital operator), 3

-

(RS485), 4 (option 1), 5 (option 2)

1203h

Base frequency setting

A003

R/W

30 to "maximum frequency"

1 [Hz]

1204h

Maximum frequency setting

A004

R/W

30 to 400

1 [Hz]

 

 

 

 

0 (switching between O and OI terminals), 1

 

 

 

 

 

(switching between O and O2 terminals), 2 (switching

 

1205h

[AT] selection

A005

R/W

between O terminal and keypad potentiometer), 3

-

(switching between OI terminal and keypad

 

 

 

 

potentiometer), 4 (switching between O2 and keypad

 

 

 

 

 

potentiometer)

 

 

 

 

 

0 (single), 1 (auxiliary frequency input via O and OI

 

1206h

[O2] selection

A006

R/W

terminals) (nonreversible), 2 (auxiliary frequency

-

input via O and OI terminals) (reversible), 3 (disabling

 

 

 

 

O2 terminal)

 

1207h to

(Reserved)

-

-

Inaccessible

-

120Ah

 

 

 

 

 

120Bh

[O]-[L] input active range

A011 (high)

R/W

0 to 40000

0.01 [Hz]

120Ch

start frequency

A011 (low)

 

 

 

120Dh

[O]-[L] input active range end

A012 (high)

R/W

0 to 40000

0.01 [Hz]

120Eh

frequency

A012 (low)

 

 

 

120Fh

[O]-[L] input active range

A013

R/W

0 to "[O]-[L] input active range end voltage"

1 [%]

start voltage

 

 

 

 

 

1210h

[O]-[L] input active range end

A014

R/W

"[O]-[L] input active range start voltage" to 100

1 [%]

voltage

 

 

 

 

 

1211h

[O]-[L] input active range

A015

R/W

0 (external start frequency), 1 (0 Hz)

-

start frequency selection

 

 

 

 

 

1212h

External frequency filter time

A016

R/W

1 to 30 or 31 (500 ms filter ±0.1 Hz with hysteresis)

1

const.

 

 

 

 

 

1213h

Easy sequence function

A017

R/W

0 (disabling), 1 (enabling)

-

selection

 

 

 

 

 

1214h

(Reserved)

-

R/W

Inaccessible

-

1215h

Multispeed operation

A019

R/W

0 (binary), 1 (bit)

-

selection

 

 

 

 

 

1216h

Multispeed frequency setting

A020 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1217h

A020 (low)

R/W

 

 

 

1218h

Multispeed 1 setting

A021 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1219h

A021 (low)

R/W

 

 

 

121Ah

Multispeed 2 setting

A022 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

121Bh

A022 (low)

R/W

 

 

 

121Ch

Multispeed 3 setting

A023 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

121Dh

A023 (low)

R/W

 

 

 

121Eh

Multispeed 4 setting

A024 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

121Fh

A024 (low)

R/W

 

 

 

1220h

Multispeed 5 setting

A025 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1221h

A025 (low)

R/W

 

 

 

1222h

Multispeed 6 setting

A026 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1223h

A026 (low)

R/W

 

 

 

1224h

Multispeed 7 setting

A027 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1225h

A027 (low)

R/W

 

 

 

1226h

Multispeed 8 setting

A028 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1227h

A028 (low)

R/W

 

 

 

1228h

Multispeed 9 setting

A029 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1229h

A029 (low)

R/W

 

 

 

122Ah

Multispeed 10 setting

A030 (high)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

122Bh

Multispeed 11 setting

A030 (low)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

122Ch

A031 (high)

R/W

 

122Dh

Multispeed 12 setting

A031 (low)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

122Eh

A032 (high)

R/W

 

122Fh

Multispeed 13 setting

A032 (low)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1230h

A033 (high)

R/W

 

1231h

Multispeed 14 setting

A033 (low)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1232h

A034 (high)

R/W

 

1233h

Multispeed 15 setting

A034 (low)

R/W

0 or "start frequency" to "maximum frequency"

0.01 [Hz]

1234h

A035 (high)

R/W

 

4 - 145

Page 203
Image 203
Hitachi SJ700-2 instruction manual List of registers function modes