Hitachi SJ700-2 instruction manual Station No. Command Parameter Data

Models: SJ700-2

1 274
Download 274 pages 15.86 Kb
Page 182
Image 182

Chapter 4 Explanation of Functions

(viii)07 command: This command writes data to a specified setting item in the inverter. - Transmission frame

Frame format

STX

Station No. Command Parameter

Data

BCC

CR

 

Description

Data size

Setting

STX

Control code (Start of TeXt)

1 byte

STX (0x02)

Station No.

Station number of control-target

2 bytes

01 to 32, or FF (broadcast to all stations)

inverter

 

 

 

Command

Command to be transmitted

2 bytes

07

Parameter

Data parameter number

4 bytes

See Note 14.

Data

Parameter data (decimal ASCII

8 bytes

See Note 13.

code)

 

 

 

BCC

Block check code

2 bytes

XOR of the items from "Station No." to "Data."

See Item (3) of this section.

 

 

 

CR

Control code (Carriage Return)

1 byte

CR (0x0D)

Note 14: Possible range of parameters is as follows.

F002-, A001-, b001-, C001-, H001-, P001- (F001 is written with 01 command.)

- Response frame

Positive response: See Item (2)-(i) of this section.

Negative response: See Item (2)-(ii) of this section.

(ix) 08 command: This command initializes specified settings in the inverter.

The setting items to be initialized follow the setting of the initialization mode (b084). When "b084" is "00", the trip history data is cleared.

-Transmission frame Frame format

STX

Station No. Command

BCC

CR

 

Description

Data size

Setting

STX

Control code (Start of TeXt)

1 byte

STX (0x02)

Station No.

Station number of control-target

2 bytes

01 to 32, or FF (broadcast to all stations)

inverter

 

 

 

Command

Command to be transmitted

2 bytes

08

BCC

Block check code

2 bytes

XOR of the items from "Station No." to "Data."

See Item (3) of this section.

 

 

 

CR

Control code (Carriage Return)

1 byte

CR (0x0D)

- Response frame

Positive response: See Item (2)-(i) of this section.

Negative response: See Item (2)-(ii) of this section.

4 - 124

Page 182
Image 182
Hitachi SJ700-2 instruction manual Station No. Command Parameter Data, Parameter data decimal Ascii Bytes See Note Code