Hitachi SJ700-2 instruction manual Failure time

Models: SJ700-2

1 274
Download 274 pages 15.86 Kb
Page 207
Image 207

Chapter 4 Explanation of Functions

Register

Function name

Function

R/W

Monitoring and setting items Data resolution

Register

No.

code

No.

 

 

 

 

 

 

 

0 (tripping), 1 (starting with 0 Hz), 2 (starting with

 

1301h

Selection of restart mode

b001

R/W

matching frequency), 3 (tripping after deceleration

-

 

 

 

 

and stopping with matching frequency), 4 (restarting

 

 

 

 

 

with active matching frequency)

 

1302h

Allowable under-voltage power

b002

R/W

3 to 250

0.1 [sec.]

failure time

 

 

 

 

 

1303h

Retry wait time before motor

b003

R/W

3 to 1000

0.1 [sec.]

restart

 

 

 

 

 

1304h

Instantaneous power

b004

R/W

0 (disabling), 1 (enabling), 2 (disabling during

-

failure/under-voltage trip alarm

 

enable

 

 

stopping and decelerating to stop)

 

 

 

 

 

 

1305h

Number of restarts on power

b005

R/W

0 (16 times), 1 (unlimited)

-

failure/under-voltage trip events

 

 

 

 

 

1306h

Phase loss detection enable

b006

R/W

0 (disabling), 1 (enabling)

-

1307h

Restart frequency threshold

b007 (high)

R/W

0 to 40000

0.01 [Hz]

1308h

b007 (low)

R/W

 

 

 

 

 

 

 

0 (tripping), 1 (starting with 0 Hz), 2 (starting with

 

1309h

Selection of retry after tripping

b008

R/W

matching frequency), 3 (tripping after deceleration

-

 

 

 

 

and stopping with matching frequency), 4 (restarting

 

 

 

 

 

with active matching frequency)

 

130Ah

Selection of retry count after

b009

R/W

0 (16 times), 1 (unlimited)

-

undervoltage

 

 

 

 

 

130Bh

Selection of retry count after

b010

R/W

1 to 3

1 [time]

overvoltage or overcurrent

 

 

 

 

 

130Ch

Retry wait time after tripping

b011

R/W

3 to 1000

0.1 [sec.]

130Dh

Electronic thermal setting

b012

R/W

200 to 1000

0.1 [%]

(calculated within the inverter

 

from current output)

 

 

 

 

130Eh

Electronic thermal characteristic

b013

R/W

0 (reduced-torque characteristic), 1 (constant-torque

-

 

 

 

 

characteristic), 2 (free setting)

 

130Fh

(Reserved)

-

-

Inaccessible

-

1310h

Free setting, electronic thermal

b015

R/W

0 to 400

1 [Hz]

frequency (1)

 

 

 

 

 

1311h

Free setting, electronic thermal

b016

R/W

0 to Rated current

0.1 [A]

current (1)

 

 

 

 

 

1312h

Free setting, electronic thermal

b017

R/W

0 to 400

1 [Hz]

frequency (2)

 

 

 

 

 

1313h

Free setting, electronic thermal

b018

R/W

0 to Rated current

0.1 [A]

current (2)

 

 

 

 

 

1314h

Free setting, electronic thermal

b019

R/W

0 to 400

1 [Hz]

frequency (3)

 

 

 

 

 

1315h

Free setting, electronic thermal

b020

R/W

0 to Rated current

0.1 [A]

current (3)

 

 

 

 

 

 

 

 

 

0 (disabling), 1 (enabling during acceleration and

 

1316h

Overload restriction operation

b021

R/W

constant-speed operation), 2 (enabling during

-

constant-speed operation), 3 (enabling during

mode

 

 

 

acceleration and constant-speed operation [speed

 

 

 

 

 

 

 

 

 

 

increase at regeneration])

 

1317h

Overload restriction setting

b022

R/W

200 to 2000

0.1 [%]

1318h

Deceleration rate at overload

b023

R/W

10 to 3000

0.01

restriction

[sec.]

 

 

 

 

 

 

 

 

0 (disabling), 1 (enabling during acceleration and

 

1319h

Overload restriction operation

b024

R/W

constant-speed operation), 2 (enabling during

-

constant-speed operation), 3 (enabling during

mode (2)

 

 

 

acceleration and constant-speed operation [speed

 

 

 

 

 

 

 

 

 

 

increase at regeneration])

 

131Ah

Overload restriction setting (2)

b025

R/W

200 to 2000

0.1 [%]

131Bh

Deceleration rate at overload

b026

R/W

10 to 3000

0.01

restriction (2)

[sec.]

 

 

 

 

131Ch

Overcurrent suppression enable

b027

R/W

0 (disabling), 1 (enabling)

-

131Dh

Active frequency matching scan

b028

R/W

200 to 2000

0.1 [%]

start frequency

 

 

 

 

 

131Eh

Active frequency matching,

b029

R/W

10 to 3000

0.01

scan-time constant

[sec.]

 

 

 

 

131Fh

Active frequency matching,

b030

R/W

0 (frequency at the last shutoff), 1 (maximum

-

 

restart frequency select

 

 

frequency), 2 (set frequency)

 

 

 

 

 

0 (disabling change of data other than "b031" when

 

 

 

 

 

SFT is on), 1 (disabling change of data other than

 

1320h

Software lock mode selection

b031

R/W

"b031" and frequency settings when SFT is on), 2

-

(disabling change of data other than "b031"), 3

 

 

 

 

(disabling change of data other than "b031" and

 

 

 

 

 

frequency settings), 10 (enabling data changes

 

 

 

 

 

during operation)

 

1322h

(Reserved)

-

-

Inaccessible

-

1323h

Run/power-on warning time

b034 (high)

R/W

0 to 65535

1 [10h]

1324h

b034 (low)

R/W

 

 

 

4 - 149

Page 207