Chapter 8 List of Data Settings

 

 

 

 

 

Default

Setting

Change

 

 

 

 

 

 

during

during

 

 

Code

Function name

Monitored data or setting

 

 

 

 

operation

operation

Page

 

 

 

 

_FF

 

_FEF

_FUF

(allowed

(allowed

 

 

 

 

 

 

or not)

or not)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ter mi nal

C111

Overload setting (2)

0.0 to 2.00 x "rated current" (A)

Rated current of inverter

{

{

4-40

Adjust ment

C121

[O] input zero calibration

0. to 9999., 1000 to 6553 (10000 to 65530)

Factory setting

{

{

 

C122

[OI] input zero calibration

0. to 9999., 1000 to 6553 (10000 to 65530)

Factory setting

{

{

-

 

 

C123

[O2] input zero calibration

0. to 9999., 1000 to 6553 (10000 to 65530)

Factory setting

{

{

 

 

C130

Output 11 on-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C131

Output 11 off-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C132

Output 12 on-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C133

Output 12 off-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C134

Output 13 on-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C135

Output 13 off-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C136

Output 14 on-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

4-72

 

C137

Output 14 off-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

 

 

 

C138

Output 15 on-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C139

Output 15 off-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C140

Output RY on-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

 

C141

Output RY off-delay time

0.0 to 100.0 (s)

 

0.0

 

¯

{

 

function

C142

Logical output signal 1 selection 1

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

C143

Logical output signal 1 selection 2

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

 

 

 

operation

C144

Logical output signal 1 operator

00 (AND), 01 (OR), 02 (XOR)

 

00

 

¯

{

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C145

Logical output signal 2 selection 1

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

terminal

C146

Logical output signal 2 selection 2

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

C147

Logical output signal 2 operator

00 (AND), 01 (OR), 02 (XOR)

 

00

 

¯

{

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

C148

Logical output signal 3 selection 1

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

C149

Logical output signal 3 selection 2

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

 

 

 

 

C150

Logical output signal 3 operator

00 (AND), 01 (OR), 02 (XOR)

 

00

 

¯

{

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C151

Logical output signal 4 selection 1

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

4-66

 

C152

Logical output signal 4 selection 2

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

 

 

 

C153

Logical output signal 4 operator

00 (AND), 01 (OR), 02 (XOR)

 

00

 

¯

{

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C154

Logical output signal 5 selection 1

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

C155

Logical output signal 5 selection 2

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

C156

Logical output signal 5 operator

00 (AND), 01 (OR), 02 (XOR)

 

00

 

¯

{

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C157

Logical output signal 6 selection 1

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

C158

Logical output signal 6 selection 2

Same as the settings of C021 to C026 (except those of LOG1 to LOG6)

 

00

 

¯

{

 

 

C159

Logical output signal 6 operator

00 (AND), 01 (OR), 02 (XOR)

 

00

 

¯

{

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C160

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

setting 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C161

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

setting 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C162

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

response

setting 3

 

 

 

 

 

 

 

 

 

 

 

 

C163

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

setting 4

 

 

 

 

 

 

 

 

 

 

 

 

 

terminal

C164

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

4-72

Input terminal response time

 

 

 

 

setting 5

 

 

 

 

 

 

 

 

Input

C165

setting 6

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

 

 

 

 

 

 

 

 

C166

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

 

 

 

 

setting 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C167

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

setting 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C168

Input terminal response time

0. to 200. ( ¯2ms)

 

1

 

¯

{

 

 

setting FW

 

 

 

 

 

 

 

 

 

 

 

 

 

Other

C169

determination time

0. to 200. ( ¯10ms)

 

0

 

¯

{

4-108

 

 

Multistage speed/position

 

 

 

 

 

 

 

4-48

 

 

 

 

 

 

 

 

 

 

 

8 - 12