Chapter 4 Explanation of Functions

(iii) List of registers (monitoring)

Register

Function name

Function code

R/W

Monitoring and setting items

Data

No.

resolution

 

 

 

 

1001h

Output frequency monitoring

d001 (high)

R

0 to 40000

0.01 [Hz]

1002h

d001 (low)

 

 

 

 

1003h

Output current monitoring

d002

R

0 to 9999

0.1 [A]

1004h

Rotation direction minitoring

d003

R

0: Stopping, 1: Forward rotation, 2: Reverse

0.1 [Hz]

rotation

 

 

 

 

 

1005h

Process variable (PV), PID

d004 (high)

R

0 to 9990

0.1

1006h

feedback monitoring

d004 (low)

 

 

 

1007h

Intelligent input terminal status

d005

R

2^0: Terminal 1 to 2^7: Terminal 8

1 bit

1008h

Intelligent output terminal

d006

R

2^0: Terminal 11 to 2^4: Terminal 15

1 bit

status

 

 

 

 

 

1009h

Scaled output frequency

d007 (high)

R

0 to 39960

0.01

100Ah

monitoring

d007 (low)

 

 

 

100Bh

Actual-frequency monitoring

d008 (high)

R

-40000 to +40000

0.01 [Hz]

100Ch

d008 (low)

R

 

 

 

100Dh

Torque command monitoring

d009

R

-200 to +200

1 [%]

100Eh

Torque bias monitoring

d010

R

-200 to +200

1 [%]

100Fh

(Reserved)

-

-

Inaccessible

-

1010h

Torque monitoring

d012

R

-200 to +200

1 [%]

1011h

Output voltage monitoring

d013

R

0 to 6000

0.1 [V]

1012h

Power monitoring

d014

R

0 to 9999

0.1 [kW]

1013h

Cumulative power monitoring

d015 (high)

R

0 to 9999999

0.1

1014h

d015 (low)

 

 

 

 

1015h

Cumulative operation RUN

d016 (high)

R

0 to 999900

0.1

1016h

time monitoring

d016 (low)

 

 

 

1017h

Cumulative power-on time

d017 (high)

R

0 to 999900

1 [h]

1018h

monitoring

d017 (low)

 

 

 

1019h

Heat sink temperature

d018

R

-200 to 2000

0.1 []

monitoring

 

 

 

 

 

101Ah

Motor temperature monitoring

d019

R

-200 to 2000

0.1 []

101Bh

(Reserved)

-

-

Inaccessible

-

101Ch

 

 

 

 

 

101Dh

Life-check monitoring

d022

R

2^0: Capacitor on main circuit board

1 bit

2^1: Low cooling-fan speed

 

 

 

 

 

101Eh to

(Reserved)

-

-

Inaccessible

-

1025h

 

 

 

 

 

1026h

DC voltage monitoring (across

d102

R

0 to 9999

0.1 [V]

P and N)

 

 

 

 

 

1027h

BRD load factor monitoring

d103

R

0 to 1000

0.1 [%]

1028h

Electronic thermal overload

d104

R

0 to 1000

0.1 [%]

monitoring

 

 

 

 

 

1029h to

(reserved)

-

-

Inaccessible

-

102Dh

 

 

 

 

 

102Eh

User monitor 1

d025(HIGH)

R

-2147483647 to 2147483647

1

102Fh

d025(LOW)

R

 

 

 

1030h

User monitor 1

d026(HIGH)

R

-2147483647 to 2147483647

1

1031h

d026(LOW)

R

 

 

 

1032h

User monitor 1

d027(HIGH)

R

-2147483647 to 2147483647

1

1033h

d027(LOW)

R

 

 

 

1034h

Pulse counter

d028(HIGH)

R/W

0 to 2147483647

1

1035h

d028(LOW)

R/W

 

 

 

1036h

Position setting monitor

d029(HIGH)

R

-2147483647 to 2147483647

1

1037h

d029(LOW)

R

 

 

 

1038h

Position feedback monitor

d030(HIGH)

R

-2147483647 to 2147483647

1

1039h

d030(LOW)

R

 

 

 

103Ah to

Unused

-

 

Inaccessible

-

1102h

 

 

 

 

 

(iv) List of registers

Register

Function name

Function code

R/W

Monitoring and setting items

Data

No.

resolution

 

 

 

 

1103h

Acceleration (1) time setting

F002 (high)

R/W

1 to 360000

0.01 [sec.]

1104h

F002 (low)

 

 

 

 

1105h

Deceleration (1) time setting

F003 (high)

R/W

1 to 360000

0.01 [sec.]

1106h

F003 (low)

 

 

 

 

1107h

Keypad Run key routing

F004

R/W

0 (forward rotation), 1 (reverse rotation)

-

1108h to

Unused

-

-

Inaccessible

-

1200h

 

 

 

 

 