LG Electronics General Wall Mounted-Inverter Type manual Special Mode Controls, Jet Cool operation

Models: General Wall Mounted-Inverter Type

1 67
Download 67 pages 5.96 Kb
Page 12
Image 12

Part 2 Functions & Controls

3. SpecialModeControls

3.1 Jet Cool operation

In the heating mode or Fuzzy operation, the Jet cool function does not work.

When it is input while in other mode of operation (cooling, dehumidification, ventilation), the Jet cool operation takes place.

In the Jet cool mode, the indoor fan is operated at super-high speed for 30 min. at cooling mode operation.

In the Jet cool mode, the room temperature is maintained at a setting temperature of 18°C(64.4°F).

When the sleep timer mode is input during the Jet cool operation, the Jet cool mode has the priority.

When the Jet cool button is pressed, the upper/lower vane of the unit is reset to those of the initial cooling mode and then operate so that the air outflow could reach further.

3.2 Jet Heat operation

While in cooling mode or Fuzzy operation, the Jet Heat function does not work.

When it is input while in the Heating mode operation (dehumidification), the Jet Heat mode operation takes place

In the Jet Heat mode, the indoor fan operated at super-high speed for 60 min. at Heating mode operation.

In the Jet Heat mode, the room temperature is maintained at a temperature of 30°C(86°F).

When the sleep timer mode is input during the Jet Heat mode operation, the Jet Heat mode has the priority.

When the Jet Heat button is pressed, the upper/lower vane of the unit is the unit reset to those of the initial Jet heating mode and then operates so that the air outflow could reach under flow.

3.3 Energy saving operation in cooling mode

During cooling and dehumidification mode of operation, the Energy saving button can be input.

In this operation, before we feel cold the set temperature and air volume is set automatically to save energy.

The operation time and the other thing was decided by experiment.

12Room Air Conditioner

Page 12
Image 12
LG Electronics General Wall Mounted-Inverter Type manual Special Mode Controls, Jet Cool operation, Jet Heat operation