LG Electronics General Wall Mounted-Inverter Type manual Electronic Parts Troubleshooting Guide

Models: General Wall Mounted-Inverter Type

1 67
Download 67 pages 5.96 Kb
Page 41
Image 41

Part 4 Trouble Shooting

6. ElectronicPartsTroubleshootingGuide

Trouble 1

The Product doesn’t operate at all. (9~30kBtu/h Model)

Turn off the main power and wait until LED on outdoor PCB is off.

Turn on the main power again.

Does "Beeping" sound is made from the indoor unit?

Does "Lighting" LED is mounted on the outdoor PCB?

NO

Check the voltage of power(AC 208~230V, 60Hz).

The voltage of main power.

The voltage applied to the unit.

The connecting method of Indoor/Outdoor connecting cable (each color)

The P.W.B. Ass'y

(Fuse,Noise Filter, Power Module(SMPS), IC01D,IC04D)

YES

Primarily, the operating condi- tion of Micom is O.K.

Check CN-DISP1

The operation check of the P.C.B. Ass'y

 

 

Procedure

Specification

Remedy

 

 

 

 

 

1)

The input voltage of Power

: DC 220V~390V

 

 

 

Module(SMPS)

 

 

2)

The output voltage of Power

: 15V 10%

Replace the P.C.B.

 

 

 

Module (SMPS)

 

 

3)

IC01D(LD1085), IC04D(7805)

: DC 5V

 

 

 

 

 

 

Service Manual 41

Page 41
Image 41
LG Electronics General Wall Mounted-Inverter Type Electronic Parts Troubleshooting Guide, Procedure Specification Remedy