Samples for Grounding

There is two of samples for grounding below.

Using a grounding wire

Determine the size of an external ground wire according to Article 690.46, NEC2014.

(Equipment grounding conductors smaller than 6 AWG shall be protected from physical damage.)

A grounding conductor with insulation or bare (no insulation) may be used, provided the terminations are reliably available.

Grounding wire

AC junction box

Using listed EGC

• Use equipment grounding conductors approved by Article 250.118, NEC2014.

Bonding jumper

EGC

(ex. metal rack)

grounding wire

AC junction box

LG AC module includes DC cables in the module’s internal wiring, so no grounding is required for DC input.

For equipment grounding, LG AC Module uses an external grounding equipment conductor. AC cable does not provide a grounding conductor, grounding is provided only by the external connection to the module frame.

17

Page 17
Image 17
LG Electronics LGxxxA1C-B3, LGENBOX-01 installation instructions Samples for Grounding