6-2 EnerBox

Internal Communication with AC module

 

 

 

Type

Broadband Power Line Communication (IEEE 1901)

 

 

Sample Rate

15 minutes

 

 

 

 

 

 

 

 

Bandwidth

2 MHz ~ 28 MHz

 

 

 

 

 

 

 

 

Transmission Rate

10Mbps

 

 

Max Node

 

50

 

 

 

 

 

 

 

 

 

 

 

 

External

Communication

 

 

 

 

Wired Communication

10/100 auto-sensing, auto-negotiating, 802.3

 

 

 

 

 

Wireless Communication (Only for Installation)

IEEE 802.11 b/g/n compatible W-LAN (Local)

 

 

 

 

Power

Requirements

 

 

 

 

AC Supply

120 VAC, 60 Hz

 

 

 

 

 

 

 

Power Consumption @ DC 12V

3.8 watts typical, 5.4 watts maximum

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical

Properties

 

 

 

 

Dimensions (W X D X H)

150 mm x 101.8 mm x 32.7 mm

 

 

(5.9 in x 4.0 in x 1.3 in)

 

 

 

 

 

 

 

 

Weight

210 g (7.4 oz.)

 

 

Temperature Range

0 ~ 40 (32 ~ 104), Installed Indoors

 

 

 

 

 

 

 

 

 

Enclosure Rating

 

IP20

 

 

 

 

Certification

 

 

 

 

 

 

 

 

 

 

Certifications

UL 60950-1, FCC Part 15 Class B

 

 

Limited Warranty

2 years

 

 

 

 

 

 

 

 

 

 

 

 

 

Wireless LAN Module(TWFM-B600D, FCC ID : BEJTWFMB006D)

Specification

 

IEEE802.11b

IEEE802.11g

 

IEEE802.11n

Frequency

 

2.4 ~ 2.484GHz

2.4 ~ 2.484GHz

 

2.4 ~ 2.484GHz

 

 

 

 

 

 

 

Modulation

 

DSSS/CCK

OFDM

 

OFDM

DATA rate

 

1,2,5.5,11Mbps

6,9,12,18,24,36,

 

6.5,13,19.5,26,39,

 

48,54Mbps

 

52,58.5,65Mbps

 

 

 

 

 

 

 

 

Min

 

13 dBm

13 dBm

 

11 dBm

 

 

 

 

 

 

 

 

RF Power

 

Typ

 

15 dBm

15 dBm

 

13 dBm

 

 

 

 

 

 

 

 

 

 

Max

 

17 dBm

17 dBm

 

15 dBm

Sensitivity

 

Min

 

-87dBm @8%PER

-72dBm @10%PER

 

-72dBm @10%PER

 

 

 

 

 

 

 

 

Max

 

-10dBm @8%PER

-30dBm @20%PER

 

-30dBm @10%PER

 

 

 

 

33