Connect the hot conductors and neutral conductor in a general AC cable from the AC junction box to the designated terminal in the distribution panel.
Then, connect conductors in transition cables to the AC junction box as shown above.

AC output three phase 208VAC - split type

To form balanced three phases, it is recommended to use 3-array equal to the number of AC modules in each array . Below is other example for AC output cables connection of three phase 208VAC.

 

 

0 0 0 0 0

Meter

 

 

 

2-pole

3-pole

 

 

 

(Determined

 

 

20A

 

 

according to the

 

 

 

 

 

 

total current)

X11

 

 

 

 

X11

 

 

 

 

X11

 

 

 

 

 

 

N L1L2L3

G

 

 

 

An array of AC modules

AC junction box

Distribution panel

 

 

 

 

 

Transition Cable (Array ÷ AC Junction Box)

Conductor

Color

 

Description

L1

Black

 

Line to neutral voltage 120VAC.

L2

Red

 

Line to neutral voltage 120VAC.

Neutral

White

 

Common conductor used in the AC module for voltage measurements.

 

 

External Equipment Grounding Conductor (Array ÷ Distribution Panel)

Ground

Green

 

Conductor to connect normally non–current carrying metal parts of equipment together.

 

 

 

General Cable (AC Junction Box ÷ Distribution Panel)

L1

Black

 

Line to neutral voltage 120VAC.

L2

Red

 

Line to neutral voltage 120VAC.

L3

Blue

 

Line to neutral voltage 120VAC.

L1-L2

-

 

Line to line voltage 208VAC.

L2-L3

-

 

Line to line voltage 208VAC.

L3-L1

-

 

Line to line voltage 208VAC.

Neutral

White

 

Neutral wire.

Step 1. Connect the equipment grounding conductor from arrays of the AC modules system to the terminal for grounding in the distribution panel.

Step 2. 1

2

Step 3. Check the cables to verify they have not been pulled too tight or are hanging too loose. If necessary, fixate them using the cable fixing holes on PV module frame with fixing holders, such as cable ties, so that the cables do not touch the ground.