– 240VAC, 208VAC
Before connecting general AC cable from the AC junction box to distribution panel, adhere to the following items:
Notice
•To prevent the danger of electric shock, check again if the circuit breaker is surely turned off.
•LG does not provide separate general AC cables between AC junction box and the distribution panel.
•Install using certified materials and system components.
•Do not put in any liquid. There is a danger of electric shock.
•Do not use any damaged cables.
•Do not cut or transform the dedicated cables for use.
•There is an extra wire in the transition cable. Do not use it.
The wire is blocked by a shrink tube at section of the outer jacket and works on shrink tubes must be done at the factory only.
Checking Accessory
L1
L2
Neutral
Male transition cable | Female transition cable |
Neutral is a common conductor uses only for AC module voltage measurement reference. This conductor does not carry current under normal or abnormal conditions.
WARNING
•To prevent property damage or danger to human life by fire or explosion, do not connect any consumable device between AC module and the circuit breaker.
•To prevent the danger of the electric shock, make sure to turn off the circuit breaker.
•Make sure to use the dedicated cable provided by LG Electronics. Outside parts may cause critical danger.
18