2)Connection of piping Indoor

Preparing the indoor unit's piping and drain hose for installation through the wall.

Remove the plastic tubing retainer(see illustration below) and pull the tubing and drain hose away from chassis.

Replace the plastic tubing holder in the original posi- tion.

Tubing holder

CAUTION

When install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable.

For right rear piping

1.Route the indoor tubing and the drain hose in the direction of rear right.

Drain hose

2.Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

3.Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.

Loop

 

Connecting

Gas side

piping

cable

 

Drain hose

Liquid side

piping

NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

*Foamed polyethylene or equivalent is recommended.

4.Indoor unit installation

Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the instal- lation plate.) Ensure that the hooks are properly seat- ed on the installation plate by moving it left and right.

Connecting cable

Drain hose

Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

4.Connecting the pipings to the indoor unit and drain hose to drain pipe.

Align the center of the pipes and sufficiently tighten the flare nut by hand.

Indoor unit tubing