Remote Control Operation Mode

When the remote control is selected by the slide switch on the main unit, the appliance operates according to the input by the remote control.

Protection of the evaporator pipe from frosting

If the indoor pipe temp is below 0°C in 7 min. after the compressor operates without any pause while in cool- ing cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor evaporator pipe from frosting.

When the indoor pipe temp is 7°C or higher after 3 min. pause of the compressor, the compressor and the outdoor fan is turned on according to the condition of the room temperature.

Buzzer Sounding Operation

When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.

When the appliance-pause key is input by the remote control, the long "beep— " sounds.

When a key is input by the remote control while the slide switch on the main unit of the appliance is on the forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the remote control signal cannot be received.