LG Electronics LS-Q096ABM Jet Cool Mode Operation C/O Model, Jet Cool Mode Operation H/P Model

Models: LS-Q096AEL LS-Q076ABL LS-Q096ADL LS-Q096BBG LS-Q096ADG LS-Q096ABM LS-Q076ABG LS-Q096ABL LS-Q096ACG LS-Q096ABG LS-Q076BBG LS-Q076BEL LS-Q096BEL

1 82
Download 82 pages 22.67 Kb
Page 20
Image 20

Jet Cool Mode Operation (C/O Model)

If the Jet Cool key is input at any operation mode while in appliance operation, the Jet Cool mode operates.

In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.

In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C

When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.

When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then operated in order that the air outflow could reach further.

Jet Cool Mode Operation (H/P Model)

While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.

In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.

In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C.

When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.

When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then operated in order that the air outflow could reach further.

Forced Operation

Operation procedures when the remote control can't be used.

The operation will be started if the power button is pressed.

If you want to stop operation, re-press the button.

 

Cooling Model

 

Heat pump Model

 

 

 

 

 

 

Room Temp. 24°C

21°C Room Temp. < 24°C

Room Temp. < 21°C

 

 

 

 

 

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

 

 

 

 

 

Setting Temperature

22°C

22°C

23°C

24°C

 

 

 

 

 

While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to indicate the forced operation.

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room tem- perature and resets in 18±1 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about 3 seconds.

If you want to stop the operation, re-press the button.

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

Air Cleaner Operation

When an air cleaner function is selected during Air Conditioner operation

-Plasma air cleaner function will be operated while in any operation mode with selecting the function.

-The function is to be stopped while it is operating with selecting the function.

When an air cleaner function is selected during operation off

-The function will be only operated.

When inlet grille of air conditioner is opened during plasma operation, High Voltage Generator(H.V.B) is to be stopped. When inlet grille of air conditioner is closed during plasma operation, High Voltage Generator(H.V.B) will be operated again.

-20-

Page 20
Image 20
LG Electronics LS-Q096ABM Jet Cool Mode Operation C/O Model, Jet Cool Mode Operation H/P Model, Forced Operation