3) How to fix installation plate

The wall you select should be strong and solid enough to prevent vibration

1.Mount the installation plate on the wall with four type A screws. If mounting the unit on a concrete wall, use anchor bolts.

Mount the installation plate horizontally by aligning the centerline using a level.

Installation Plate

Type "A" screw

2.Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typi- cally. Drilling the hole through the wall for piping connections must be done safely.

4)Drill a hole in the wall

Drill the piping hole with a ø 70mm hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.

 

WALL

Indoor

Outdoor

 

 

 

 

 

 

 

5-7mm

(3/16"~5/16")

 

 

C

Installation plate

D

A

Ø70mm

B

Ø70mm

Left rear pipingRight rear piping

CHASSIS

 

Distance (mm)

 

(Grade)

 

 

 

 

A

B

C

D

 

SJ

90

20

80

20

 

 

 

 

 

SL, SK

45

40

80

20

 

 

 

 

 

SQ

75

12

80

12

 

 

 

 

 

SR

0

40

20

40

 

 

 

 

 

ST

105

0

210

0

 

 

 

 

 

Installation plate

D

 

 

B

C

E

A

Left rear piping

Right rear piping Ø70mm

 

CHASSIS

 

 

Distance (mm)

 

 

(Grade)

 

 

 

 

 

 

 

A

B

 

C

 

D

E

 

 

 

SM

180

115

 

-

 

115

50

SN

180

115

 

195

 

115

-

 

 

 

 

 

 

 

 

-24-

Page 24
Image 24
LG Electronics LS-Q096ADG, LS-Q096BBG, LS-Q096ACG, LS-Q076ABL How to fix installation plate, Drill a hole in the wall