LG Electronics LS-Q076BBG, LS-Q096BBG Connecting The Cable Between Indoor Unit and Outdoor Unit

Models: LS-Q096AEL LS-Q076ABL LS-Q096ADL LS-Q096BBG LS-Q096ADG LS-Q096ABM LS-Q076ABG LS-Q096ABL LS-Q096ACG LS-Q096ABG LS-Q076BBG LS-Q076BEL LS-Q096BEL

1 82
Download 82 pages 22.67 Kb
Page 30
Image 30

3.Connecting The Cable Between Indoor Unit and Outdoor Unit

1)Connect the cable to the Indoor unit.

Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of the indoor unit.)

The earth wire should be longer than the common wires.

CAUTION

When installing, refer to the circuit diagram on the Control Box of Indoor Unit.

When installing, refer to the wiring diagram on the Control Cover Inside Outdoor Unit.

CAUTION

The above circuit diagram is subject to change with- out notice.

Be sure to connect wires according to the wiring dia- gram.

Connect the wires firmly, so that not to be pulled out easily.

Connect the wires according to color codes by refer- ring the wiring diagram.

CAUTION

If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.

The power cord connected to the "A" unit should be complied with the following specifications

(Type "B" approved by HAR or SAA).

 

 

 

 

 

 

(mm2)

NORMAL

 

 

Grade

 

 

CROSS

 

 

 

 

 

 

5k~9K

12k~14k

18k

24k~28k

30k, 32k

36k, 38k

-SECTIONAL

0.75

1.0

1.5

2.5

2.5

5.5

AREA

Unit(A)

Indoor

Indoor

Indoor

Indoor

Outdoor

Outdoor

Cable Type(B) H05VV-F H05VV-F H05VV-F H05VV-F H05RN-F H05RN-F

The power connecting cable connected to the indoor and outdoor unit should be complied with the following specifications

(Type "B" approved by HAR or SAA).

Main power source

Air

 

Circuit Breaker

Conditioner

 

Use a circuit

 

 

breaker or time

 

 

 

 

delay fuse.

 

 

 

 

(mm2)

NORMAL

 

Grade

 

CROSS

 

 

 

 

5k~9k

12k~14k

18k

24k~28k

-SECTIONAL

0.75

1.0

1.5

2.5

AREA

Cable Type(B) H07RN-F H07RN-F H07RN-F H07RN-F

(mm2)

NORMAL CROSS

Grade

 

 

30k, 32k

36k, 38k

-SECTIONAL AREA

0.75

0.75

 

 

 

 

Cable Type(B)

H07RN-F

H07RN-F

 

 

 

NORMAL CROSS-SECTIONAL AREA 0.75mm2

-30-

Page 30
Image 30
LG Electronics LS-Q076BBG Connecting The Cable Between Indoor Unit and Outdoor Unit, Connect the cable to the Indoor unit