ALARM
COM
Equivalent Diagram

LVC-SX703PC_AA4HEL_ENG_MFL-129 11/7/06 12:05 PM Page 14

External Device Connections

RS-485 (TR+)

RS-485 (TR-)

ALARM (OUT)

ALARM (COM)

MULTI (INPUT)

MULTI (GND)

RS-485 Connection

Connect to an external controller of RS-485 format.

Alarm Connection

Connect an external device such as a buzzer or lamp to the ALARM terminal. When the camera detects motion, the alarm output signal is supplied to the connected external device.

14

Contact Ratings

• Maximum load current is ±130mA.

• Do not connect any system or device that has over 40 Vp-p (DC 30 V) bias voltage on the contact terminal.

Notes:

Use a relay unit if the voltage or current of the connected device exceeds the ratings.

Multi-Input Connection

Connect an external device to use HOT KEY func- tion. The HOT KEY function is operated when the input signal is “ON”. To set the HOT KEY function, see page 35.

The Multi-Input terminal has the register of DC 3.3V pull-up. The sink current must be less than 0.8mA.

OFF: Open contact

ON: Closed contact

Page 14
Image 14
LG Electronics LVC-SX703PC/OC/MC External Device Connections, RS-485 Connection, Alarm Connection, Multi-Input Connection