Switches

Four switches for the control of functions as described in Table 35.

Table 35 Switches

Designation

Description

 

 

EQUALIZE MAN/AUTO

Used to activate or deactivate the equalize function.

 

 

ACO

Used to cancel the audible alarm signal.

 

 

CALIBRATE NORM/CAL

Used to activate or deactivate the calibration function.

 

 

CONT rotary switch

Six position switch: OFF, AMP, CHG VOLT, BAT VOLT, CAL, TST DISPL

 

 

DIP switches

Three DIP switch modules for the setting of functions as described in Table 36 and as shown in

Figure 27 and Figure 28.

Table 36 DIP switch modules

Designation

Description

 

 

SHUNT SELECT

To select the shunt size

 

 

TIMER

To select the duration of the equalize

 

 

VOLT

To select the equalize voltage

 

 

Figure 27 Shunt range selection settings

 

 

 

S1

 

 

RANGE AMPS

1

2

3

4

5

6

MIN-MAX

 

 

 

 

 

 

 

55 to 100

 

 

 

 

 

 

100 to 170

 

 

 

 

 

 

170 to 340

 

 

 

 

 

 

340 to 500

 

 

 

 

 

 

500 to 1000

 

 

 

 

 

 

1000 to 1700

 

 

 

 

 

 

1700 to 3400

 

 

 

 

 

 

3400 to 7000

 

 

 

 

 

 

7000 to 14000

 

 

= SWITCH IS ON

 

 

30 Operation

Page 36
Image 36
Liebert 3000, 4000, 6000 A, 1500 user manual Switches, DIP switches, DIP switch modules

1500, 6000 A, 4000, 3000 specifications

The Liebert 3000 is a cutting-edge power protection solution designed to provide reliable and efficient backup power for critical applications. This uninterruptible power supply (UPS) system is engineered to safeguard sensitive electronic equipment from power disturbances, ensuring uninterrupted operations in data centers, telecommunications, and industrial environments.

One of the standout features of the Liebert 3000 is its high-efficiency design. With an efficiency rating of up to 94%, the system minimizes energy loss, resulting in lower operational costs and a reduced carbon footprint. This is particularly important in today's environmentally conscious climate, as organizations strive to meet sustainability goals while maintaining top-tier performance.

The Liebert 3000 employs advanced technologies to enhance its functionality. It incorporates online double-conversion technology, which provides a continuous supply of clean and regulated power. This technology ensures that connected loads receive stable voltage and frequency, shielding them from voltage spikes, sags, and outages. Additionally, the UPS offers features such as automatic battery testing, which helps ensure peak battery performance and reliability.

Another key characteristic of the Liebert 3000 is its modular design, allowing for flexible scalability. This means that organizations can easily expand the capacity of their UPS system as their power needs grow, without the need for extensive system overhauls. The modular architecture also facilitates simplified maintenance and reduces downtime, as individual modules can be serviced without interrupting power to the critical load.

The system is equipped with comprehensive monitoring and management capabilities. The Liebert 3000 provides real-time data on power usage, battery status, and system performance, enabling facility managers to make informed decisions and proactively address potential issues. The integration of remote management tools allows for seamless monitoring from anywhere, providing peace of mind for operators.

Overall, the Liebert 3000 combines high efficiency, advanced technology, and flexible design to deliver a robust power protection solution. Its reliability and performance make it a preferred choice for organizations seeking to protect their critical infrastructure while enhancing operational efficiency and sustainability. As businesses continue to rely on technology for their everyday operations, the Liebert 3000 stands out as a dependable safeguard against the uncertainties of power quality.