Semiannual Maintenance Inspection Checklist

9.0SEMIANNUAL MAINTENANCE INSPECTION CHECKLIST

Date:________________________________________

Model #:_____________________________________

Filters

___ 1. Restricted air flow

___ 2. Check filter switch

___ 3. Wipe section clean

Blower Section

___ 1. Impellers free of debris and move freely

___ 2. Check belt tension and condition

___ 3. Bearings in good condition

___ 4. Inspect & tighten electrical connections

Compressor

___ 1. Check oil leaks

___ 2. Check for leaks

___ 3. Inspect & tighten electrical connections

Air Cooled Condenser (if applicable)

___ 1. Condenser coil clean

___ 2. Motor mounts tight

___ 3. Bearings in good condition

___ 4. Refrigerant lines properly supported

___ 5. Inspect & tighten electrical connections

Water/Glycol Condenser (if applicable)

___ 1. Copper tube clean

___ 2. Water regulating valves function

___ 3. Glycol solution

___ 4. Check for water/glycol leaks

Glycol Pump

___ 1. Glycol leaks

___ 2. Pump operation

___ 3. Inspect & tighten electrical connections

Notes

Prepared by:_________________________________

Serial #:_____________________________________

Steam Generating Humidifier

___ 1. Check canister for deposits

___ 2. Check condition of steam hoses

___ 3. Check water make-up valve for leaks

___ 4. Inspect & tighten electrical connections

Infrared Humidifier

___ 1. Check pan drain for clogs

___ 2. Check humidifier lamps

___ 3. Check pan for mineral deposits

___ 4. Inspect & tighten electrical connections

Refrigeration Cycle/Section

___ 1. Check refrigerant lines

___ 2. Check for moisture (sight glass)

___ 3. Check suction pressure

___ 4. Check head pressure

___ 5. Check discharge pressure

___ 6. Check hot gas bypass valve

___ 7. Check thermostatic exp. valve

Air Distribution Section

___ 1. Restriction in grille free area

Refrigerant Charge

___ 1. Check refrigerant level

Electrical Panel

___ 1.

Check fuses

___ 2.

Inspect & tighten electrical connections

___ 3.

Check operation sequence

___ 4.

Check contactor operation

Reheat

___ 1. Check reheat element operation

___ 2. Inspect elements for cleanliness

___ 3. Inspect & tighten electrical connections

Signature

Make photocopies of this form for your records

65

Page 73
Image 73
Liebert 3000 manual Filters, Water/Glycol Condenser if applicable, Glycol Pump, Electrical Panel, Reheat

3000 specifications

The Liebert 3000 is a cutting-edge power protection solution designed to provide reliable and efficient backup power for critical applications. This uninterruptible power supply (UPS) system is engineered to safeguard sensitive electronic equipment from power disturbances, ensuring uninterrupted operations in data centers, telecommunications, and industrial environments.

One of the standout features of the Liebert 3000 is its high-efficiency design. With an efficiency rating of up to 94%, the system minimizes energy loss, resulting in lower operational costs and a reduced carbon footprint. This is particularly important in today's environmentally conscious climate, as organizations strive to meet sustainability goals while maintaining top-tier performance.

The Liebert 3000 employs advanced technologies to enhance its functionality. It incorporates online double-conversion technology, which provides a continuous supply of clean and regulated power. This technology ensures that connected loads receive stable voltage and frequency, shielding them from voltage spikes, sags, and outages. Additionally, the UPS offers features such as automatic battery testing, which helps ensure peak battery performance and reliability.

Another key characteristic of the Liebert 3000 is its modular design, allowing for flexible scalability. This means that organizations can easily expand the capacity of their UPS system as their power needs grow, without the need for extensive system overhauls. The modular architecture also facilitates simplified maintenance and reduces downtime, as individual modules can be serviced without interrupting power to the critical load.

The system is equipped with comprehensive monitoring and management capabilities. The Liebert 3000 provides real-time data on power usage, battery status, and system performance, enabling facility managers to make informed decisions and proactively address potential issues. The integration of remote management tools allows for seamless monitoring from anywhere, providing peace of mind for operators.

Overall, the Liebert 3000 combines high efficiency, advanced technology, and flexible design to deliver a robust power protection solution. Its reliability and performance make it a preferred choice for organizations seeking to protect their critical infrastructure while enhancing operational efficiency and sustainability. As businesses continue to rely on technology for their everyday operations, the Liebert 3000 stands out as a dependable safeguard against the uncertainties of power quality.