Series 600T Multi-Module Systems, 500-750 kVA - 480 Volt Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter

Required

Maximum

 

 

 

 

 

 

 

 

 

 

Rectifier

or

Battery

Battery

Maximum

Dimen-

Approx.

Floor

 

 

 

 

 

 

AC

Bypass

Discon-

Current

Heat Dis-

Loading

UPS

 

 

 

Input

AC Output

nect

at End of

sipation

sions

Weight

Lb./

Rating

 

Options

Current

Current

Rating

Discharge

BTU/hr.

Inches

Lb.

Sq.ft.

 

 

 

AC

 

Input

 

 

 

 

 

 

 

 

 

(Concen-

 

 

 

Output

Input

Iso

 

 

 

 

 

 

Full

 

(Un-

trated

kVA

 

kW

Voltage

Filter

Xfmr

Nom

Max

Nom

Max

Amps

Amps

Load

(WxDxH)

packed)

Loading)

500

 

400

480

NO

NO

602

753

601

752

1,000

1,079

87,150

72x39x79

5,710

293

500

 

400

480

YES

NO

558

698

601

752

1,000

1,079

91,800

72x39x79

5,910

303

500

 

400

480

NO

YES

612

765

601

752

1,000

1,079

110,700

96x39x79

8,710

335

500

 

400

480

YES

YES

565

707

601

752

1,000

1,079

115,500

96x39x79

8,910

343

500

 

450

480

NO

NO

677

847

601

752

1,200

1,214

98,050

72x39x79

5,730

294

500

 

450

480

YES

NO

628

785

601

752

1,200

1,214

103,250

72x39x79

5,930

304

500

 

450

480

NO

YES

688

861

601

752

1,200

1,214

124,550

96x39x79

9,030

347

500

 

450

480

YES

YES

638

798

601

752

1,200

1,214

129,931

96x39x79

9,230

355

625

 

500

480

NO

NO

749

936

752

936

1,400

1,349

99,300

108x39x79

7,405

285

625

 

500

480

YES

NO

694

867

752

936

1,400

1,349

105,050

108x39x79

7,625

293

625

 

500

480

NO

YES

757

946

752

936

1,400

1,349

118,650

120x39x79

10,485

323

625

 

500

480

YES

YES

701

877

752

936

1,400

1,349

124,509

120x39x79

10,705

329

750

 

600

480

NO

NO

898

1123

902

1128

1,600

1,619

119,200

108x39x79

8,005

308

750

 

600

480

YES

NO

833

1041

902

1128

1,600

1,619

126,100

108x39x79

8,225

316

750

 

600

480

NO

YES

908

1135

902

1128

1,600

1,619

142,350

120x39x79

11,485

353

750

 

600

480

YES

YES

842

1052

902

1128

1,600

1,619

149,410

120x39x79

11,705

360

750

 

675

480

NO

YES

1022

1277

902

1128

1,600

1,822

160,150

120x39x79

11,785

363

750

 

675

480

YES

YES

947

1184

902

1128

1,600

1,822

168,100

120x39x79

12,005

369

Applicable

13

1,4,5,7,8,

2,3,5,7,8,

6

6,8,9,

14

14

Notes:

 

 

 

 

9,11,12

9,11,12

 

11,12

 

 

 

 

For explanation of notes, see referenced numbers in 12.1 - Notes

Appendix A - Site Planning Data

81

Page 87
Image 87
Liebert 600TTM installation manual Series 600T Multi-Module Systems, 500-750 kVA 480 Volt Input