Blocking for Safety

Mounting the anti tipping device in cabinets deeper than 24" -

Figure 10 - 11

To ensure the compressor mounting plate reaches the anti tipping bracket in cabinets deeper than 24", a wooden spacer must be mounted between the appliance back and the wall. The anti tipping bracket will be fastened to the floor downwards and to the spacer backwards.

Be sure the wooden spacer is fastened securely to the floor.

Measuring for mounting the wooden spacer on inset kitchen cabinets - Figure 10

Depth of spacer depending on clearance between appliance and wall

Panel thickness

Figure 10

Measuring for mounting the wooden spacer on frameless kitchen cabinets - Figure 11

Depth of spacer depending on clearance between appliance and wall

Figure 11

IMPORTANT

If the floor slopes down sideways, the anti- tipping bracket must be fitted horizontally. Lay down spacers in the appropriate positions.

Cover strips - Figure 12

Before connection to the water supply, the cover strips provided must be fitted to the appliance. It is necessary because the appliance will be moved into its recess.

Remove the cover band from the strips and stick them to the left and right front edge of the appli- ance housing (Figure 12).