Lincoln 1400, 1200, 1000 1 on 2 on, 3 on 4 off 5 off 6 off, Burner Motor Centrifugal Switch bad

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 24
Image 24

1 on 2 on

3 on 4 off 5 off 6 off

- Burner Motor Centrifugal Switch bad.

1 on 2 on

3 on 4 on 5 off 6 off

- Ignition Control bad.

1 on 2 on

3 on 4 on 5 on 6 off

- Pilot Shield missing or warped, Flame Sensor bad, Pilot

 

 

- Orifice plugged, or Gas Valve bad.

1 on 2 on 3 on 4 on 5 on 6 on

- Unit still not working Main Orifice plugged, Gas Valve bad,

 

 

- Temperature Control bad.

 

 

- However, Main Orifice would not be intermittent problem.