Lincoln 1200, 1400, 1000 service manual Gas Valve - Replacement And Adjustments

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 55
Image 55
GAS VALVE - REPLACEMENT AND ADJUSTMENTS

THE FOLLOWING ITEMS ARE USED IN THE MODEL 1030, 1046, 1047 IMPINGER OVEN (EXPORT)

AIR PRESSURE SWITCHES - REPLACEMENT AND ADJUSTMENT

1.Remove control panel top.

2.Disconnect wires from switch making note of wire number and location for reinstallation.

3.Remove air tube from switch assembly.

4.Remove switch from wire hanger.

5.Install new switch in reverse order, make sure air tube is not blocked miss-aligned. Adjust as needed.

To adjust the air pressure switch, remove snap on cover on the side of the switch to expose adjusting screw. To increase sensitivity, turn screw counter clockwise; to decrease sensitivity, turn screw clockwise. Check for proper line voltage switching from N.C. to N.O. as the air pressure switch closes.

GAS VALVE - REPLACEMENT AND ADJUSTMENTS

1.Remove control panel top and front cover.

2.Disconnect the gas piping from the back of the unit.

3.Remove the four (4) screws from the incoming nipple mounting bracket.

4.Remove incoming nipple.

5.Disconnect two (2) plugs, (1 ) 3 prong and (1 ) 4 prong - Note location.

6.Disconnect pipe union just above gas valve and remove assembly.

7.Reassemble in reverse order (check all pipe fittings for leaks). After assembled, check for proper adjustment of gas pressure switch, 8.8 on dial for natural gas, 23 for L.P. Gas and 4.5 for town gas.

8.Check and adjust manifold pressure. Remove pressure tap located in gas piping above the gas valve prior to the burner orifice and install manometer . Adjustment screw is located on the front of the valve, remove plastic cap and adjust as needed: 3.5" W.C. for Natural Gas and 10" W.C. for L.P.

9.Check gas filter by removing cover plate (located on either side of valve). Remove four

(4) screws and slide filter out of valve housing and inspect. Reassemble in reverse order and check for leaks around cover.

SIDE VIEW

FILTER

COVER

PLATE

PRESSURE CONTROLLER ADJUSTMENT

FILTER

Manual backgroundCOVER

PLATE

 

TOP VIEW

 

 

 

 

 

OUTPUT

 

 

 

MANIFOLD

 

 

 

PRESSURE

 

 

 

ADJUSTMENT

 

+

 

 

 

 

gnd

ELECTRICAL

-

1

2

CONNECTOR

 

 

 

3

 

 

3

 

 

2

 

 

ELECTRICAL

 

 

 

 

gnd

 

CONNECTOR

Impinger I -–1000 Series Service Manual - Domestic

55

Page 55
Image 55
Lincoln 1200, 1400, 1000 service manual Gas Valve - Replacement And Adjustments