Lincoln 1400, 1200, 1000 service manual Dip Switch, Switch Replacement Fan, Heat, Conveyor

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 54
Image 54

Dip Switch

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

TYPE I

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

TYPE II

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

TYPE III

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

NOTE: When on 50 HZ power, dip switch #2 must be "ON"

 

 

 

 

With power ON turn time and temperature cal. pot. fully counterclockwise.

 

 

 

Display should read: (Wait 15-20 seconds)

 

 

 

 

 

 

TYPE I 9:30 + 10 sec.475 + 10°F

 

 

 

 

 

 

 

TYPE II 9:20 + 10 sec. HHH

 

 

 

 

 

 

 

TYPE III

9:35 + 10 sec. 635 + 10°F

 

 

 

 

 

 

 

Turn time and temp. cal. pot. fully clockwise.

 

 

 

 

 

 

Display should read: (Wait 15-20 seconds)

 

 

 

 

 

 

TYPE I 10:20 + 10 sec.

615 + 10°F

 

 

 

 

 

 

 

TYPE II 10:10 + 10 sec.

475 + 10°F

 

 

 

 

 

 

 

TYPE III

10:20 + 10 sec.

475 + 10°F

 

 

 

 

 

 

 

Turn time pot. to 10:00 minutes and temp. pot. to 540°F. Time reading 10:00 ± 5 seconds.

Temperature reading should be steady at 540°F + 10°F. If these readings are not achieved, replace display.

NOTE: After simulator test is completed, the oven Time/Temperature Display must be re-calibrated.

SWITCH REPLACEMENT (FAN, HEAT, CONVEYOR)

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove switch access cover.

4.Depress the spring clips on the sides of the switch and push out.

5.Remove wires from back of switch. Note wire number and location.

6.Install new switch in reverse order and check.

SWITCH REPLACEMENT - (FAN SWITCH UPDATE)

INSTALLATION OF DOUBLE POLE FAN SWITCH #369260 IN PLACE OF SINGLE POLE FAN SWITCH #350705

NOTE:

This change is not necessary for proper operation of oven nor is it

 

permissible to change under warranty. Should be changed only at

 

customer©s request and their agreement to pay your bill.

ADVANTAGE:

Allows time/temp. display, in older models, to operate same as current

 

production models. Also allows locked time/temp. display (caused by

 

voltage surge, interruption or spike) to be reset by fan switch rather than

 

circuit breaker.

IDENTIFICATION:

To determine which fan switch you have, observe if temperature displays

 

stays on during cooling down. If it stays on , you have the single pole

 

switch. If it goes out as soon as fan switch is turned off you have the double

 

pole switch.

REPLACEMENT:

Replace single pole switch # 350705.

 

Install double pole switch # 369260.

 

Disconnect lead indicated by # in proper diagram and reroute as shown.

 

Install jumper lead indicated by * in proper diagram.

 

Reapply all other leads as removed.

54

Impinger I -–1000 Series Service Manual - Domestic

Page 54
Image 54