Lincoln 1200, 1400, 1000 Manifold Pressure - Adjustment, Temperature Control Valve Robert Shaw

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 37
Image 37

MANIFOLD PRESSURE - ADJUSTMENT

1.Remove control panel top and front cover.

2.WITH ELECTRIC POWER AND GAS OFF: remove the outlet pressure tap plug from the gas control valve and install the adapter fitting and manometer.

3.Turn on electric power and gas and start-up oven.

4.With oven at full fire, manifold pressure should be (3.5"W.C. NAT/10" W.C. LP).

5.Turn off electric power and gas, replace cover screw, remove manometer and adapter; replace pressure tap plug.

6.Check pressure tap for gas leaks before closing panel.

7.Close control panel and check system operation.

TEMPERATURE CONTROL VALVE (ROBERT SHAW)

1.Shut off power at main breaker

2.Shut off gas supply.

3.Remove control panel top and front cover.

4.Remove gas control valve (See Above).

5.Remove the two-(2) 3/8" x 16 nuts that hold main orifice bracket to the burner assembly.

6.Remove temperature control valve sensing bulb from oven cavity.

NOTE: It may be necessary to remove conveyor and fingers from oven cavity.

7.Remove piping from old temperature control valve.

8.Reassemble in reverse order, be sure the sensing bulb is properly placed in the oven cavity. The sensing bulb is properly placed in the oven cavity when it is placed in

the spring holder and positioned with the 5 1/2" of the bulb to the left of the spring holder. NOTE: The bypass screw should be adjusted all the way in.

SOLENOID VALVE

1.Shut off power at main breaker.

2.Shut off gas supply.

3.Remove control panel top and front cover.

4.Remove gas control valve (See "GAS CONTROL VALVE").

5.Disconnect wires from solenoid valve.

6.Remove two (2) 3/8" x 16 hex nuts that hold main orifice bracket in place.

7.Remove solenoid valve assembly.

8.Remove piping from solenoid valve.

9.Reassemble in reverse order.

TEMPERATURE CONTROL BOARD

GAS OVENS

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove relay box cover.

4.Disconnect wiring from temperature control board.

5.Make note of wire number and location for reinstallation.

6.Reassemble in reverse order.

ELECTRIC OVENS

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Disconnect wiring from temperature control board.

4.Make note of wire numbers and location for reinstallation.

5.Reassemble in reverse order.

Impinger I -–1000 Series Service Manual - Domestic

37

Page 37
Image 37
Lincoln 1200, 1400, 1000 service manual Manifold Pressure - Adjustment, Temperature Control Valve Robert Shaw, Solenoid Valve