Lincoln 1000 BEARING, CONVEYOR SN 2164 AND ABOVE, Transformer-Steppermotor Control, Drive End

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 50
Image 50
BEARING, CONVEYOR

BEARING, CONVEYOR

SN 2164 AND ABOVE

1.Remove conveyor from oven and place on a flat work surface.

2.Remove connecting links from conveyor belting. See Installation and Operating Instructions Manual .

3.Remove conveyor belting from conveyor

DRIVE END

4.Remove drive sprocket from drive shaft.

5.Remove two (2) allen head bolts.

6.Remove drive shaft and bearing assembly from conveyor frame.

7.Reassemble in reverse order.

IDLER END

4.Remove idler shaft/bearing/mounting plate assembly from conveyor frame.

5.Remove bearing/mounting plate assembly from conveyor.

6.Remove bearing from mounting plate.

7.Reassemble in reverse order.

TRANSFORMER-STEPPER MOTOR CONTROL

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Disconnect transformer wire harness.

4.Remove two (2) mounting screws.

5.Reassemble in reverse order.

HALL EFFECT SENSOR – REPLACEMENT

NOTE: There are two (2) styles of hall effect sensors - (See Drawing).

OLD STYLE

Remove two (2) screws from conveyor drive motor and break away hall effect sensor from motor shaft. To install new sensor, cut sensor bracket through center hole and install sensor

half with one (1) screw. Reinstall plug on conveyor control.

NEW STYLE

Remove two (2) mounting screws and remove sensor from conveyor motor. Reinstall in reverse order.

CUT

HERE

DISCARD

OLD STYLE

NEW STYLE