STEPPER CONTROL - ADJUSTMENT

STEPPER CONTROL - ADJUSTMENT

S/N 14975 AND ABOVE 1000 SERIES GAS OVEN

S/N 14792 AND ABOVE 1200 SERIES GAS OVEN

CURRENT SENSE

DO NOT ADJUST

Heat Sink

MOTOR

 

 

 

 

 

 

 

 

 

J 6

J 3

 

 

 

 

J 1

J 4

 

 

J 5

 

5

4

3

2

1

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

Max.

Min.

 

 

 

Blue

Red

Brown

Red

Conveyor

Conveyor

 

 

 

 

 

 

Gray

POWER

Speed Adj.

Speed Adj.

 

 

 

 

 

 

LOCKED ROTOR

 

 

 

 

 

 

 

 

POTENTIOMETER

 

 

To T/T display

Black to #4

 

TIME/TEMP

White to #7

 

 

 

 

 

1.With power off, the five (5) dip switches located on the conveyor control (see drawing above) should be set as below.

 

DIP SWITCHES

 

 

CONTROL

1

2

3

4

5

SWITCH POSITION

OFF

OFF

ON

OFF

OFF

2.With power off, the ten (10) dip switches located on rear of Time/Temp Display (see drawing on page 52) should be set as below.

DISPLAY

1

2

3

4

5

6

7

8

9

10

 

SWITCH POSITION OFF

*

*

ON

OFF

OFF

ON

ON

OFF

ON

 

*SWITCH 2

- OFF FOR 60HZ, ON FOR 50HZ

 

 

 

 

 

*SWITCH 3

- OFF FOR °F, ON FOR °C

 

 

 

 

 

3.With conveyor running, set conveyor speed control so Time/Temp. Display indicates 5:00 minutes. Place a pan on the conveyor, measure (STOPWATCH) the time (SPEED OF PAN) of the leading edge in to leading edge out of oven. Turn the speed adjustment pot. on the rear of the Time/Temp. Display so display agrees with time measured by the stop watch. (See drawing on page 52).

4.Turn conveyor speed control fully counterclockwise and adjust the stepper control maximum speed pot (refer to drawing above) so the display indicates 50 seconds.

5.Turn conveyor speed control fully clockwise and adjust the stepper control minimum speed

pot so the display indicates 30 minutes.

NOTE: Repeat 4 and 5 to be sure settings are accurate.

6.Turn power off and set #1 dip switch to its (ON/OFF) other position and verify that the conveyor reverses direction when power is applied. Set conveyor travel direction as customer requests.

CAUTION: ALWAYS REMOVE POWER BEFORE CHANGING CONVEYOR DIRECTION.