Lincoln 1200, 1400, 1000 service manual Thermostat, Cooling Fan, Burner Blower Motor

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 34
Image 34
THERMOSTAT, COOLING FAN

THERMOSTAT, COOLING FAN

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove lead wires and mark for reassembly.

4.Remove two (2) screws and remove thermostat.

5.Reassemble in reverse order.

BURNER BLOWER MOTOR

1.Shut off power at main breaker.

2.Remove control panel top and front panel.

NOTE: Complete burner blower motor assembly, with control box (p/n 369359), is no longer available. The burner blower assembly (p/n 369265) has been changed to a burner motor kit

(p/n 369366). When It is used in the 3 ft Impinger Gas oven, the following modification must be made:

3.Remove control box and components mounted on burner blower motor.

4.Mount transformer on air switch bracket as shown (use transformer as template).

5.Remove three (3) screws that attach blower assembly to burner housing.

6.Mount new blower assembly.

7.Wire as shown. See page 35.

8.Discard control box and relay.

9.Transfer air shutter assembly from old blower assembly to new blower assembly. MATERIAL NEEDED: #29 drill bit and #8 x 3/8 self tapping screws (3 each)

AIR SWITCH MOUNTING BRACKET

MOUNTING HOLES (USE #29 DRILL) #8 X 3/8

SELF TAPPING SCREW

SEPARATE GROUND SCREW