Check to see if the conveyor drive (stepper) motor

Time Display inaccurate, erratic, or inoperative(S/N Q19078 & Above1000 Series) (S/N Q14791 & Above1200 Series)

 

Perform all checks as in the above evaluation. If

 

the time check is okay, refer to the next section.

Conveyor Drive (Stepper)

Check to see if the conveyor drive (stepper) motor

Control

is running. If motor is not running, refer to

 

"Conveyor will not run" on page 28.

Magnet

Check to insure that the magnet (cemented to shaft

 

of conveyor drive (stepper) motor) has not been

 

damaged, or come loose from motor shaft.

 

Replace as needed.

Hall Effect Sensor

Check for any physical damage to Hall Effect

 

sensor (mounted on conveyor drive(stepper)

 

motor). Check all wiring and connections for

 

damage.

Conveyor Drive (Stepper)

Check all connections for tightness or proper

Control

location and check all wiring for visible damage.

 

Replace as needed. If there is still no time display,

 

wire in (temporarily) a new conveyor drive control.

 

If there is still no time display, reconnect original

 

conveyor drive control. Replace Hall Effect Sensor.