Lincoln 1400, 1200 Temperature Gauge - Replacement, Thermistor - Replacement, Oven Temperature

Models: 1000 1200 1400

1 92
Download 92 pages 51.22 Kb
Page 51
Image 51
TEMPERATURE GAUGE - REPLACEMENT

TEMPERATURE GAUGE - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top.

3.Disconnect thermocouple from temperature gauge.

4.Remove two (2) mounting bolts and remove temperature gauge.

5.Reassemble in reverse order.

THERMISTOR - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top.

3.Slide thermistor probe out of oven chamber.

NOTE: Remove conveyor and bottom fingers to aid in removal and instaliaticn of thermistor probe.

4.Disconnect wires from back of digital display at terminal strip (location #9-10).

5.Reassemble in reverse order making sure the probe is placed securely in the wire form in the oven chamber.

6.Reconnect to digital display and calibrate. (See Time/Temperature Display - Replacement and Calibration)

To test the thermistor probe, refer to the following chart and instructions

OVEN TEMPERATURE

 

300º F

325º F

350º F

400º F

425º F

450º F

500º F

550º F

OHMS

182

138

102

62

48

38

24

16

Place test pyrometer thermocouple and preheat oven as specified under temperature calibration. Disconnect the thermistor probe from terminals 9 and 10 and measure the resistance across the 2 yellow leads. Refer to the above chart to determine if probe is producing the proper resistance.

EXAMPLE: The probe resistance at 500°F(260°©C) should be 24 ohms.

TRANSFORMER, TIME/TEMP. DISPLAY

1.Shut off power at main breaker.

2.Remove control panel top.

3.Remove relay box cover.

4.Disconnect two (2) wires at base of transformer and three (3) wires at terminals 1,2, and 3 on Time/Temp Display.

5.Remove two (2) mounting screws.

6.Reassemble in reverse order.

TIME/TEMPERATURE DISPLAY - REPLACEMENT & CALIBRATION

1.Shut off power at main breaker.

2.Remove control panel top.

3.Disconnect wires from rear of display. Make note of wire numbers and location for reinstallation.

4.Remove four (4) screws from display bezel (2 top/2 bottom) and remove display.

5.Install new display in reverse order. Note dip switch position and calibrate display as follows:

a)Check all wire connections to insure proper tightness.

b)Check dip switch setting to insure proper positions for the model of oven:

Impinger I -–1000 Series Service Manual - Domestic

51

Page 51
Image 51
Lincoln 1400 Temperature Gauge - Replacement, Thermistor - Replacement, Oven Temperature, Transformer, Time/Temp. Display