B-11

 

OPERATION

B-11

 

 

 

 

 

 

USER DEFINED PARAMETERS (CONT.)

 

Parameter

Definition

 

 

 

 

P.15

Hot-Inch Touch Sense Option

 

This option allows enabling or disabling touch sense when feeding wire forward.

Disabled = Touch sensing is disabled when feeding the wire forward (default).

Enabled = Touch sensing is active when feeding the wire forward.

 

 

When enabled and feeding wire forward, the wire is electrically "hot" and waiting to short to the

 

 

plate. When a short occurs, the wire feed automatically stops and the flux hopper relay is acti-

 

 

vated until the feed forward button is released.

 

P.18

Wire Drive Gear Ratio

 

 

This option selects the Wire Drive Gear Ratio that will be used. This applies to the Cruiser dX

 

 

Tractor and MAXsa 10 only. The possible selectable values are read from the Wire Drive on

 

 

startup.

 

 

Note: Changing this value will cause the system to reset.

 

 

 

 

P.21

Shutdown 2 Function Select

 

 

This option allows selection of the Shutdown 2 input function on the control box. Normal

 

 

Shutdown = The Shutdown 2 input functions as a standard shutdown input that locks out all

 

 

input buttons (default) Output Disable = The Shutdown 2 input functions as a machine output

 

 

lockout to disable the welding circuit but still allow cold feeding of the wire.

 

 

 

 

P.23

Trigger Fan-Out

 

 

For Sub-Arc Lead Arc machines only. Allows the Lead Arc MAXsa10 to control all machine trig-

 

 

gers in a multi-arc system.

 

 

No = Only the machine connected to the MAXsa10 can be triggered on and off (default).

 

 

Yes = All machines in the system can be triggered on and off simultaneously.

 

 

 

 

P.30

Input Control

 

 

This option allows the front panel controls of the MAXsa 10 to be enabled/disabled. The remote

 

 

inputs are always functional when connected, but there may be applications where it is neces-

 

 

sary to disable the inputs on the pendent. Panel & Remote = All pendent buttons are enabled

 

 

(default). Panel Locked = The Start, Flux and feed buttons are disabled at the pendent. The

 

 

pendent's Stop button is always active and cannot be disabled.

 

 

 

 

P.80

Sense From Studs

 

 

Use this option for diagnostic purposes only. When power is cycled, this option is automatically

 

 

reset to False.

 

 

False = Voltage sensing is automatically determined by the selected weld mode and otherma-

 

 

chine settings (default).

 

 

True = Voltage sensing is forced to "studs".

 

 

 

 

P.99

Show Test Modes?

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the

 

 

machine does not include test weld modes in the list of weld modes that are available to the

 

 

operator. To manually select a test weld mode, set this option to "Yes". When the power source

 

 

is turned off and back on again, the test modes will no longer appear in the mode list. Test weld

 

 

modes typically require the machine output to be connected to a grid load and cannot be used

 

 

for welding.

 

 

 

 

P.100

View Diagnostics?

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes"

 

 

to access the diagnostic options in the menu. Additional parameters will now appear in the

 

 

setup menu (P.101, P.102, etc).

 

 

MAXsa™ 10 CONTROLLER

Page 26
Image 26
Lincoln Electric IM10023 manual Parameter Definition Hot-Inch Touch Sense Option, Wire Drive Gear Ratio, Trigger Fan-Out