| OPERATION | ||
|
|
|
|
|
| USER DEFINED PARAMETERS (CONT.) |
|
Parameter | Definition |
| |
|
|
| |
P.15 |
|
|
This option allows enabling or disabling touch sense when feeding wire forward.
Disabled = Touch sensing is disabled when feeding the wire forward (default).
Enabled = Touch sensing is active when feeding the wire forward.
|
| When enabled and feeding wire forward, the wire is electrically "hot" and waiting to short to the |
|
| plate. When a short occurs, the wire feed automatically stops and the flux hopper relay is acti- |
|
| vated until the feed forward button is released. |
| P.18 | Wire Drive Gear Ratio |
|
| This option selects the Wire Drive Gear Ratio that will be used. This applies to the Cruiser dX |
|
| Tractor and MAXsa 10 only. The possible selectable values are read from the Wire Drive on |
|
| startup. |
|
| Note: Changing this value will cause the system to reset. |
|
|
|
| P.21 | Shutdown 2 Function Select |
|
| This option allows selection of the Shutdown 2 input function on the control box. Normal |
|
| Shutdown = The Shutdown 2 input functions as a standard shutdown input that locks out all |
|
| input buttons (default) Output Disable = The Shutdown 2 input functions as a machine output |
|
| lockout to disable the welding circuit but still allow cold feeding of the wire. |
|
|
|
| P.23 | Trigger |
|
| For |
|
| gers in a |
|
| No = Only the machine connected to the MAXsa10 can be triggered on and off (default). |
|
| Yes = All machines in the system can be triggered on and off simultaneously. |
|
|
|
| P.30 | Input Control |
|
| This option allows the front panel controls of the MAXsa 10 to be enabled/disabled. The remote |
|
| inputs are always functional when connected, but there may be applications where it is neces- |
|
| sary to disable the inputs on the pendent. Panel & Remote = All pendent buttons are enabled |
|
| (default). Panel Locked = The Start, Flux and feed buttons are disabled at the pendent. The |
|
| pendent's Stop button is always active and cannot be disabled. |
|
|
|
| P.80 | Sense From Studs |
|
| Use this option for diagnostic purposes only. When power is cycled, this option is automatically |
|
| reset to False. |
|
| False = Voltage sensing is automatically determined by the selected weld mode and otherma- |
|
| chine settings (default). |
|
| True = Voltage sensing is forced to "studs". |
|
|
|
| P.99 | Show Test Modes? |
|
| Most power sources contain weld modes used for calibration and test purposes. By default, the |
|
| machine does not include test weld modes in the list of weld modes that are available to the |
|
| operator. To manually select a test weld mode, set this option to "Yes". When the power source |
|
| is turned off and back on again, the test modes will no longer appear in the mode list. Test weld |
|
| modes typically require the machine output to be connected to a grid load and cannot be used |
|
| for welding. |
|
|
|
| P.100 | View Diagnostics? |
|
| Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes" |
|
| to access the diagnostic options in the menu. Additional parameters will now appear in the |
|
| setup menu (P.101, P.102, etc). |
|
| MAXsa™ 10 CONTROLLER |