Hz

B-5

OPERATION

B-5

 

 

 

CHANGING AND SETTING WELD MODES

To select a weld mode, press the WELD MODE SELECTOR button until the WELD MODE indicator comes ON (it may already be lit by default at power up). Turn the control knob to select the desired mode. After about 1 second, the parameters for the new mode will be displayed. These parameters can be adjusted with the control knobs below each display.

NOTE: CC Modes will show AMPS in the upper left display. CV Modes will show wire feed speed and the WFS indicator will be lit.

FREQUENCY/BALANCE CONTROL

FREQUENCY ADJUST

Press the WELD MODE selector until the FREQUEN- CY/BALANCE indicator comes ON and the MSP Display reads “Frequency”. If the selected mode allows for frequency adjustment, the Control Knob can be used to select the desired frequency between 20 and 100hz.

BALANCE ADJUST

Press the WELD MODE selector until the MSP Display reads “Balance”. If the selected mode allows for balance adjustment, the Control Knob can be used to select the desired wave balance through a range of 25% to 75%.

60

Hz

Balance

1000

Increased Balance

 

Nominal Balance

More Penetration

Decreased Balance

Less Deposition

 

 

Less Penetration

500

 

More Deposition

 

 

0

 

 

-500

 

 

-1000

 

 

Adjusting the Balance (the ratio between Positive and Negative half cycle ‘on time’) changes the deposition for more efficient welding.

OFFSET ADJUST

Press the WELD MODE selector until the MSP Display reads “Offset”. If the selected mode allows for offset adjustment, the Control Knob can be used to select the desired offset. The amount of offset allowed is determined by the selected weld mode.

60

0

Hz

percent

Frequency

DC Offset

 

 

Use Frequency to fine tune stability of

1000

imbalanced waveforms and multiple arc systems

 

 

500

 

 

0

 

 

-500

 

 

-1000

Decrease

Increase

1000

500

0

-500

-1000

Positive Offset

 

 

 

 

More Penetration

Nominal Offset

Less Deposition

 

 

 

 

Negative Offset

 

 

 

 

 

 

 

 

Less Penetration

 

 

 

 

 

 

 

 

More Deposition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency adjustment can be used to fine tune stabili- ty of imbalanced waveforms and multiple arc system.

Independent control of the Positive and Negative cycles allows for more precise control of penetration and deposition.