Lincoln Electric IM10023 manual Troubleshooting, Problems Symptoms, Possible Cause

Models: IM10023

1 48
Download 48 pages 32.9 Kb
Page 41
Image 41
Manual background
1. The power source does not have any welding programs loaded.

E-6

TROUBLESHOOTING

E-6

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

ARCLINK SYSTEM ERROR CODES

Err 263 No usable weld modes.

If all recommended possible areas of misadjustment have been checked

2.See the power source Instruction and the problem persists, Contact Manual for load welding pro- your local Lincoln Authorized Field

grams.

Service Facility.

Below are errors implemented for the MAXsa™ 10.

Error

Source

UI Text

Reason

Code

 

 

 

 

 

 

 

N/A

User Interface

" Limits Exceed "

When a mode is selected with a work point low limit

 

 

"Gear Box Type"

greater than the high WFS limit. (no event is logged)

 

 

 

 

28

Feeder

“OUTPUT DISABLED”

The shutdown 2 input on the Feeder Board is open and

 

 

 

P.21 is selected for “Output Disable”

 

 

 

 

83

Feeder

" UI Shutdown 1 "

The shutdown 1 input on the Feeder Board is open.

 

 

 

 

84

Feeder

" UI Shutdown 2 "

The shutdown 2 input on the Feeder Board is open.

 

 

 

 

Typical User Interface 3 digit error codes (not blinked on the status LED).

 

Error

Source

UI Text

Reason

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

213

 

Power Source

User Interface could not communicate with control board

 

 

 

is Off-Line

in power source.

215

 

Feeder Board is Off-Line

Either no feed head board is connected, being repro-

 

 

 

 

 

grammed or experiencing a fatal event.

247

 

 

 

 

 

 

 

N/A

Arc control has a latched fault. The UI will indicate a

 

 

 

 

Reset button needs to be pressed to clear the fault.

274

 

N/A

Weld set change required clearing of user memory.

 

 

 

275

 

N/A

UI memory could not be saved. Contact Lincoln Electric

 

 

 

 

Service Department for further support.

276

 

N/A

UI memory could not be restored. Contact Lincoln

 

 

 

 

User Interface

 

Electric Service Department for further support.

 

 

 

 

 

277

 

N/A

UI memories were converted due to change in number of

 

 

 

 

UI parameters. Info only.

 

 

 

 

 

278

 

N/A

UI limits were converted due to change in number of UI

 

 

 

 

parameters with limits. Info only.

281

 

(Varies based on the

Internal Error. Collect all displayed values and contact

 

 

 

 

 

error type and who

Lincoln Electric Service Department.

 

 

 

caused the error)

 

 

 

 

282

 

(Varies based on the

Internal Error. Collect all displayed values and contact

 

 

 

 

error type and who

Lincoln Electric Service Department.

 

 

 

caused the error)

 

 

 

 

 

 

 

 

 

 

 

 

Manual backgroundManual background CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MAXsa™ 10 CONTROLLER

Page 41
Image 41
Lincoln Electric IM10023 manual Troubleshooting, Problems Symptoms, Possible Cause, Recommended Course Of Action