Lincoln Electric IM10023 manual Troubleshooting, Problems, Possible, Cause, Output

Models: IM10023

1 48
Download 48 pages 32.9 Kb
Page 42
Image 42
PROBLEMS

 

E-7

 

 

 

TROUBLESHOOTING

E-7

 

 

 

 

 

 

 

 

 

 

 

Typical User Interface 3 digit error codes (not blinked on the status LED).

 

 

 

 

 

 

 

 

 

 

 

Error

Source

 

UI Text

 

 

Reason

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

283

 

 

(Varies based on the

Internal Error. Collect all displayed values and contact

 

 

 

 

 

error type and who

Lincoln Electric Service Department.

 

 

 

 

 

caused the error)

 

 

 

 

 

 

285

 

 

 

 

 

 

 

 

 

 

 

N/A

UI memory could not be restored. Contact Lincoln

 

 

 

 

 

 

 

Electric Service Department for further support.

 

 

612

 

User Interface

{" Phase Gen Init "},

1 =

Initializing Phase Generator

 

 

 

 

 

 

{"Duplicate Arc # "},

2

=

Duplicate Arc #'s found

 

 

 

 

 

{" Mult Lead Arcs "},

3

=

Mult Lead Arcs found

 

 

 

 

 

{" Missing an Arc "},

 

4

= Missing a Trail Arc

 

 

 

 

 

{" Too Many Arcs "},

 

5 = Too Many Arcs

 

 

 

 

 

{"Missing Lead Arc"},

 

6

= Missing Lead Arc

 

 

 

 

 

{" Missing an Arc "}

7 = Trail Arc dropped communication with Lead Arc

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE

 

RECOMMENDED

 

 

 

 

(SYMPTOMS)

 

CAUSE

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

PROBLEMS

 

 

 

 

 

 

The feeder does not power up - no

1. The Power Wave power source is

 

 

 

 

display, no feed.

 

OFF. Turn ON the Power Wave

 

 

 

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

 

 

2. The circuit breaker for the wire

 

 

 

 

 

 

 

 

feeder on power source has

 

 

 

 

 

 

 

 

tripped. Reset the circuit break-

 

 

 

 

 

 

 

 

ers.

 

 

 

 

 

 

 

 

 

 

3. The control cable may be loose

If all recommended possible areas of

 

 

 

 

 

 

or damaged. Tighten, repair or

 

 

 

 

 

 

replace the control cable.

 

misadjustment have been checked

 

 

 

 

 

 

 

 

 

and the problem persists, Contact

 

 

 

 

 

 

4. The power switch is damaged.

your local Lincoln Authorized Field

 

 

 

 

 

 

Replace the power switch.

 

Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

POSSIBLECAUSE CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.