B-10

 

OPERATION

B-10

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

 

Exit Setup Menu

 

 

 

 

P.0

This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit

 

 

 

the setup menu

 

 

 

 

 

 

 

 

 

 

P.1

Wire Feed Speed Units

 

 

 

 

 

 

This option selects which units to use for displaying wire feed speed. English = inches/minute

 

 

 

wire feed speed units (default). Metric = meters/minute wire feed speed units.

 

 

 

 

 

 

 

 

 

 

P.2

Arc Display Mode

 

 

 

 

 

 

This option selects what value will be shown on the upper left display while welding. Amps =

 

 

 

The left display shows Amperage while welding (default). WFS = The left display shows Wire

 

 

 

Feed Speed while welding.

 

 

 

 

 

 

 

 

 

 

P.3

Display Energy

 

 

 

 

 

 

This option selects whether or not energy is shown on the lower display while welding. The total

 

 

 

energy from the previous weld will persist on the lower display until another weld is started, or a

 

 

 

user interface control is changed. This option will only show up in the list if the power source is

 

 

 

capable of calculating energy (a power source firmware update may be necessary).

 

 

 

 

 

 

No = Energy will not be displayed (default). Yes = Energy is displayed.

 

 

 

 

 

 

 

 

 

 

P.12

Travel Carriage Start/Stop - Travel Starts

 

 

 

 

 

 

This option allows the adjustment of the start and end travel options for a travel carriage. Press

 

 

 

the Right Button to enter the option and rotate the Control Knob to select either starting or end-

 

 

 

ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to

 

 

 

select the desired function. After selecting the function, press the Left Button to save the func-

 

 

 

tion and back out to select another option. Rotate the Control Knob to make another selection,

 

 

 

or press the Left Button to exit this option.

 

 

 

 

 

 

 

 

 

 

P.12

Travel Carriage Start/Stop - Travel Ends

 

 

 

 

 

 

This option allows the adjustment of the start and end travel options for a travel carriage. Press

 

 

 

the Right Button to enter the option and rotate the Control Knob to select either starting or end-

 

 

 

ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to

 

 

 

select the desired function. After selecting the function, press the Left Button to save the func-

 

 

 

tion and back out to select another option. Rotate the Control Knob to make another selection,

 

 

 

or press the Left Button to exit this option.

 

 

 

 

 

 

 

 

 

 

P.13

Arc Force Adjustment Options

 

 

 

 

 

 

This option allows the adjustment of Arc Force values for Start, Weld and Crater. Press the

 

 

 

right Mode Select Button to enter the option and rotate the Set knob to select the desired weld

 

 

 

state to adjust. Press the right button again to adjust the value on the upper left knob. Press

 

 

 

the left button to save the value and back out to select another weld state. Rotate the Set knob

 

 

 

to make another selection, or press the left button to exit this option. P.13 will not appear if the

 

 

 

presently selected weld mode does not support Arc Force.

 

 

 

 

 

 

 

 

 

 

P.14

Reset Consumable Weight

 

 

 

 

 

 

Use this option to reset the initial weight of the consumable package. Press the Right Button to

 

 

 

reset the consumable weight. This option will only appear with systems using Production

 

 

 

Monitoring.

 

 

 

 

 

 

 

 

 

 

MAXsa™ 10 CONTROLLER

Page 25
Image 25
Lincoln Electric IM10023 manual User Defined Parameters