E-4

TROUBLESHOOTING

E-4

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

ARCLINK SYSTEM ERROR CODES

Err 35

Capacitor bank "B" overvolt-

1. The power source input power

 

 

 

age.

 

may be wired incorrectly. Verify

 

 

 

 

the power source reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

Err 36

Thermal

1.

Power source overheating. Verify

 

 

 

 

 

duty cycle is correct. Ensure ade-

 

 

 

 

quate airflow around power

 

 

 

 

source.

 

 

 

 

 

 

 

Err 41

Long term secondary over-

1.

The power source has exceeded

If all recommended possible areas of

 

current.

 

the output current limits. Adjust

misadjustment have been checked

 

 

 

the welding procedure to reduce

and the problem persists, Contact

 

 

 

the current draw. The welding

your local Lincoln Authorized Field

 

 

 

procedure may exceed the

Service Facility.

 

 

 

capacity of the power source.

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

Err 43

Capacitors are out of bal-

1.

Verify the power source recon-

 

 

 

ance

 

nect panel wiring matches the

 

 

 

 

input power.

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 