SAVING A PROCEDURE TO A MEMORY LOCATION

Once the parameters have been set:

Press and Hold the Memory Button of the desired location for 2 seconds.

The LED for that location will come ON.

After 2 seconds the LED will go OFF

The MSP display will show briefly that the informa- tion is saved, then return to the Weld Mode.

NOTE: Holding the button for longer than 5 sec- onds will enter the Limits Mode.

RECALLING A PROCEDURE FROM A MEMORY LOCATION

Press and release the desired Memory Button.

The LED for that location will come ON and the stored procedure information will show in the dis- plays.

The LED will remain ON until another location is selected

NOTE: Holding the button for longer than 1 sec- ond will re-enter the “Save” Mode.

FIGURE B.8 - MEMORY

MSP

DISPLAY

LED

INDICATOR

MEMORY BUTTON

Hold for 2 Seconds

to Save

Press and Release

to Recall

200 30.5