OPERATION | ||
|
|
|
SAVING A PROCEDURE TO A MEMORY LOCATION
Once the parameters have been set:
•Press and Hold the Memory Button of the desired location for 2 seconds.
•The LED for that location will come ON.
•After 2 seconds the LED will go OFF
•The MSP display will show briefly that the informa- tion is saved, then return to the Weld Mode.
NOTE: Holding the button for longer than 5 sec- onds will enter the Limits Mode.
RECALLING A PROCEDURE FROM A MEMORY LOCATION
•Press and release the desired Memory Button.
•The LED for that location will come ON and the stored procedure information will show in the dis- plays.
•The LED will remain ON until another location is selected
NOTE: Holding the button for longer than 1 sec- ond will
FIGURE B.8 - MEMORY
MSP
DISPLAY
LED
INDICATOR
MEMORY BUTTON
Hold for 2 Seconds
to Save
Press and Release
to Recall
200 30.5
58
Steel 1/8”
CC DC +
Memory 1
Saved
MAXsa™ 10 CONTROLLER