Lincoln Electric IM10023 manual Troubleshooting, Arclink System Error Codes

Models: IM10023

1 48
Download 48 pages 32.9 Kb
Page 38
Image 38
ARCLINK SYSTEM ERROR CODES

E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

 

ARCLINK SYSTEM ERROR CODES

 

 

Err 31

Primary overcurrent

1.

The power source has exceeded

 

 

 

 

input current limits. Adjust the

 

 

 

 

welding procedure to reduce the

 

 

 

 

current draw. The welding proce-

 

 

 

 

dure may exceed the capacity of

 

 

 

 

the power source.

 

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

Err 32

Capacitor bank "A" under

1.

The power source input power

 

 

voltage.

 

may be wired incorrectly. Verify

 

 

 

 

the power source

reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

If all recommended possible areas of

 

 

 

 

 

 

 

2.

See the power source Instruction

misadjustment have been checked

 

 

 

Manual.

 

and the problem persists, Contact

 

 

 

 

 

your local Lincoln Authorized Field

Err 33

Capacitor bank "B" under

1. The power source input power

Service Facility.

 

voltage.

may be wired incorrectly. Verify

 

 

 

the power source reconnect panel

 

 

 

wiring matches the input power.

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

1.

The power source input power

 

Err 34

Capacitor bank "A" overvolt-

 

may be wired incorrectly. Verify

 

 

age.

 

the power source

reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual backgroundManual background CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MAXsa™ 10 CONTROLLER

Page 38
Image 38
Lincoln Electric IM10023 manual Troubleshooting, Arclink System Error Codes