TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
Note: For any Err # listed below write down the error number for reference and try cycling power to see if the error clears itself. If not, refer to the What to Do column for the given Err.
| PROBLEMS | POSSIBLE CAUSE | RECOMMENDED | |
| (SYMPTOMS) | COURSE OF ACTION | ||
|
| |||
|
|
|
| |
Display shows any of the following: |
|
|
| |
|
|
|
|
|
Err | 001 | More than 1 CB with the same group | Make sure the group dip switch set- | |
|
| number. | ting is unique for each CB. | |
|
|
|
|
|
Err | 003 | Too many objects in group. | A given group can only support up to | |
|
|
| 7 objects. Remove any objects over | |
|
|
| 7 from the group either by changing | |
|
|
| the group dip switch settings or | |
|
|
| physically disconnecting any objects | |
|
|
| over 7 in the group. | |
|
|
|
| |
Err | 004 | More than 1 object of the same | Adjust the dip switch setting to make | |
|
| equipment type with the same group | either the group # or feed head # | |
|
| # and feed head #. | unique for all objects of the same | |
|
|
| equipment type. | |
|
|
|
| |
Err | 005 | A feed head has its feed head dip | The appropriate feed head # is 1 | |
|
| switches set to zero in a group with | through 7. Check the dip switch set- | |
|
| more than one object. | ting chart in INSTALLATION section | |
|
|
| and set the switches to make the | |
|
|
| Feed head ID | |
|
|
|
| |
Err | 006 | Did not receive a recognition com- | Check to see if the status light is not | |
|
| mand from the power source. | solid green on the power source | |
|
|
| (refer to status light states in OPER- | |
|
|
| ATION section if not). Also, check | |
|
|
| continuity in the communication lines | |
|
|
| from CB to Power Source (refer to | |
|
|
| wiring diagram). Refer to Power | |
|
|
| source trouble shooting section for | |
|
|
| additional information. If all these | |
|
|
| avenues fail, replace CB mother PC | |
|
|
| board. | |
|
|
|
|
|
CAUTION