E-10

TROUBLESHOOTING

E-10

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

Note: For any Err # listed below write down the error number for reference and try cycling power to see if the error clears itself. If not, refer to the What to Do column for the given Err.

 

PROBLEMS

POSSIBLE CAUSE

RECOMMENDED

 

(SYMPTOMS)

COURSE OF ACTION

 

 

 

 

 

 

Display shows any of the following:

 

 

 

 

 

 

 

 

Err

001

More than 1 CB with the same group

Make sure the group dip switch set-

 

 

number.

ting is unique for each CB.

 

 

 

 

 

Err

003

Too many objects in group.

A given group can only support up to

 

 

 

7 objects. Remove any objects over

 

 

 

7 from the group either by changing

 

 

 

the group dip switch settings or

 

 

 

physically disconnecting any objects

 

 

 

over 7 in the group.

 

 

 

 

Err

004

More than 1 object of the same

Adjust the dip switch setting to make

 

 

equipment type with the same group

either the group # or feed head #

 

 

# and feed head #.

unique for all objects of the same

 

 

 

equipment type.

 

 

 

 

Err

005

A feed head has its feed head dip

The appropriate feed head # is 1

 

 

switches set to zero in a group with

through 7. Check the dip switch set-

 

 

more than one object.

ting chart in INSTALLATION section

 

 

 

and set the switches to make the

 

 

 

Feed head ID non-zero.

 

 

 

 

Err

006

Did not receive a recognition com-

Check to see if the status light is not

 

 

mand from the power source.

solid green on the power source

 

 

 

(refer to status light states in OPER-

 

 

 

ATION section if not). Also, check

 

 

 

continuity in the communication lines

 

 

 

from CB to Power Source (refer to

 

 

 

wiring diagram). Refer to Power

 

 

 

source trouble shooting section for

 

 

 

additional information. If all these

 

 

 

avenues fail, replace CB mother PC

 

 

 

board.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER FEED 11

Page 44
Image 44
Lincoln Electric IM613-B manual Err 001, Err 003, Err 004, Err 005, Err 006