A-7

INSTALLATION

A-7

 

 

 

S2 DIP Switch Bank on Control Box Motherboard (For software version S24456-1)

Switch

Off

 

 

On

 

 

 

 

 

1

Network Group ID, MSB

(Assigns Control Box to a specific group) (Off is factory setting)

 

 

 

 

 

2

Network Group ID, LSB

(Assigns Control Box to a specific group ) (Off is factory setting)

 

 

 

 

3

4-Step Domestic Configuration

4-Step European Configuration

 

 

 

 

 

4

Power Feed 10 / Dual

 

 

Power Feed 11

 

 

 

 

5

Procedure change with trigger OFF

Procedure change with trigger ON

 

 

 

 

6

Must be off for normal operation

Adjust lower limits

 

 

 

 

7

Must be off for normal operation

Adjust upper limits

 

 

 

 

8

Must be on for all units (Permits selection of extended modes)

 

 

 

 

 

Note: the factory shipped settings for Switch S2 are as follows:

PF-11

European - Switches 1,2

& 5-7 OFF;

Switches 3,4,8 ON

PF-11

World

- Switches 1-3

& 5-7 OFF;

Switches 4, 8 ON

SETTING DIP SWITCHES IN THE WIRE

 

DRIVE

FIGURE A.4

 

There is one DIP switch bank on the control board of

 

the wire drive. Its labeled S1 and is located and ori-

 

ented as shown in Figure A.4.

S1

O N 1 2 3 4 5 6 7

8

S1 DIP Switch Bank on Wire Drive Control Board (For software version S24468-1)

Switch

Off

 

 

 

On

 

 

 

 

 

1

Network Group ID, MSB

(Assigns Wire Drive to a specific group)

 

 

 

 

 

2

Network Group ID, LSB

(Assigns Wire Drive to a specific group )

 

 

 

 

 

3

Network Feed Head ID, MSB

(Assigns feed head number to wire drive)

 

 

 

 

 

 

4

Network Feed Head ID

 

(Assigns feed head number to wire drive)

 

 

 

 

 

5

Network Feed Head ID, LSB

(Assigns feed head number to wire drive)

 

 

 

 

 

 

6

Spare

 

 

 

 

 

 

 

 

7

Electrode Sense Polarity = Positive

Electrode Sense Polarity = Negative

 

 

 

 

 

 

Switch position must match polarity of weld cable attached to feed plate.

8

Gear Box Ratio = Low

Gear Box Ratio = High

Switch position must match actual gear box ratio of wire drive.

Note: the factory shipped settings for Switches 1-7 is OFF, Switch 8 is ON.

POWER FEED 11

Page 15
Image 15
Lincoln Electric IM613-B manual Setting DIP Switches in the Wire Drive, Figure A.4