B-2

OPERATION

B-2

 

 

 

No external shielding gas is required when used with Lincoln Innershield® .035” (0.9 mm) NR-211- MP electrode.

Accommodates both 4” (100 mm) diameter and 8” (200 mm) diameter spools of wire.

WELDING CAPABILITY

The WELD-PAK 3200HD is rated at 90 amps, 19 volts, at 20% duty cycle on a ten minute basis. It is capable of higher output currents at lower duty cycles.

LIMITATIONS

Arc Gouging cannot be performed with the WELD- PAK 3200HD. The WELD-PAK 3200HD is not recom- mended for pipe thawing or TIG welding.

CONTROLS AND SETTINGS

Refer to Figure B.1a.

1.Control Power ON/OFF Switch

— When the power is on the fan motor will run and air will be exhausted out the louvers in the front of the machine. The weld-

ing output and wire feeder

OFF

remain off until the gun trigger

 

is pressed.

 

Refer to Figure B.1b.

4.Circuit Breaker – Protects machine from damage if maximum output is exceeded. Button will extend out when tripped (Manual reset) Refer to Figure B.1b.

5.Gun Trigger - Activates welding output, wire feed, and gas solenoid operation. Releasing the trigger deactivates welding and simultaneously activates the “burnback” function so that the welding wire does not stick in the weld puddle.

2.Wire Speed Control — Controls the wire feed speed from 50 – 300 in /min (1.3 – 7.6 m/min). The control can be preset on the dial to the setting specified on the W E L D P A K 3 2 0 0 H D Application Chart located on the inside of the wire feed section door.

3.Voltage Control — A 4-posi- tion tap selector switch gives full range adjustment of power source output voltage. Do not switch while welding.

ON

WIRE SPEED

ARC VOLTS

WELD-PAK 3200HD

Page 16
Image 16