D-1

 

MAINTENANCE

D-1

SAFETY PRECAUTIONS

 

 

 

WARNING

 

 

 

ELECTRIC SHOCK can kill.

 

 

• Have an electrician install and ser-

 

 

vice this equipment.

 

 

 

• Turn the input power off at the

 

 

fuse box, disconnect or unplug

 

 

supply lines and allow machine to

 

 

sit for five minutes minimum to

 

 

allow the power capacitors to dis-

 

 

charge before working inside this

 

 

equipment.

 

 

 

• Do not touch electrically hot parts.

 

----------------------------------------------------------------------

 

INPUT FILTER CAPACITOR

 

 

DISCHARGE PROCEDURE

 

 

 

WARNING

 

 

The machine has internal capacitors which are

 

charged to a high voltage during power-on condi-

 

tions. This voltage is dangerous and must be dis-

 

charged before the machine can be serviced.

 

Discharging is done automatically by the machine

 

each time the power is switched off. However, you

 

must allow the machine to sit for at least 5 min-

 

utes to allow time for the process to take place.

 

------------------------------------------------------------------------

 

ROUTINE MAINTENANCE

Prevent metal powder from accumulating near the aeration fins and over them.

Carry out the following periodic controls on the power source:

• Clean the power source inside by means of low- pressure compressed air.

• Check the electric connections and all the connec- tion cables.

• Always use gloves in compliance with the safety standards.

V310-T AC/DC TIG