A-3

INSTALLATION

A-3

5. The work terminal must be connected to a ground

RECONNECT PROCEDURE

 

 

within ten feet of the welder, using one of the fol-

 

 

lowing methods.

The Invertec V310-T AC/DC auto reconnects to 208V,

 

a) A metal underground water pipe in direct con-

230V or 460V supply.

 

 

 

tact with the earth for ten feet or more.

Fuse the input circuit with time delay fuses or delay

 

b)

A 3/4” (19mm) galvanized pipe or a 5/8”

type1 circuit breakers. Using fuses or circuit breakers

 

smaller than recommended may result in “nuisance”

 

 

(16mm) solid galvanized iron, steel or copper

shut-offs from welder inrush currents even if not weld-

 

 

rod driven at least eight feet into the ground.

ing at high currents.

 

 

The ground should be securely made and the

The Invertec V310-T AC/DC is recommended for use

 

grounding cable should be as short as possible

 

using cable of the same size as the work cable, or

on an individual branch circuit.

 

 

larger. Grounding to the building frame electrical

 

 

 

conduit or a long pipe system can result in re-radi-

Also called “inverse time” or “thermal/magnetic” circuit breakers.

 

ation, effectively making these members radiating

¹ These circuit breakers have a delay in tripping action that

 

antennas.

decreases as the magnitude of the current increases.

 

6. Keep all panels securely in place.

 

 

7. All electrical conductors within 50 ft (15.2m) of the

 

 

 

welder should be enclosed in grounded, rigid

 

 

 

metallic conduit or equivalent shielding. Flexible

 

 

 

metallic conduit is generally not suitable.

 

 

8. When the welder is enclosed in a metal building,

 

 

 

several earth driven electrical grounds connected

 

 

 

(as in 5b above) around the periphery of the build-

 

 

 

ing are recommended.

 

 

Failure to observe these recommended installation

 

 

procedures can cause radio or TV interference prob-

 

 

lems.

 

 

 

INPUT CONNECTIONS

 

 

Be sure the voltage, phase, and frequency of the input

 

 

power is as specified on the rating plate, located on

 

 

the bottom of the machine.

 

 

 

 

WARNING

 

 

 

 

ELECTRIC SHOCK can kill.

 

 

 

 

• Have a qualified electrician install

 

 

 

 

and service this equipment.

 

 

 

 

• Turn the input power OFF and unplug

 

 

 

 

the machine from the receptacle

 

 

 

 

before working on this equipment.

 

 

• Allow machine to sit for 5 minutes minimum to

 

 

allow the power capacitors to discharge before

 

 

working inside this equipment.

 

 

• Do not touch electrically hot parts.

 

 

• Machine must be plugged into a receptacle that

 

 

is grounded according to the National Electrical

 

 

Code and local codes.

 

 

• Do not remove or defeat the purpose of the

 

 

power cord ground pin.

 

 

-----------------------------------------------------------------------

 

 

 

 

V310-T AC/DC TIG

 

Page 12
Image 12
Lincoln Electric IM958 manual Reconnect Procedure, Input Connections