B-7

 

 

 

 

OPERATION

 

 

 

 

 

B-7

 

 

 

 

 

WELDING PARAMETERS

 

 

 

 

 

The following parameters are adjustable on the V310-T AC/DC. (See Table B.3)

 

 

 

Parameter

 

Table B.3

 

 

 

 

 

 

 

 

 

 

 

Parameter Name

 

 

Parameter Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

 

 

 

unit

 

Min

 

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre-Flow

 

Sec

 

0

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start Current

 

Amps

Min.

Peak

 

 

 

 

 

 

Finish Current

 

Amps

Min

Peak

 

 

 

 

 

 

 

Min. Current

 

Amps

Min

Peak

 

 

 

 

 

 

Upslope

 

Sec

 

0

 

10

 

 

 

 

 

 

 

Downslope

 

Sec

 

0

 

10

 

 

 

 

 

 

 

Spot Time

 

Sec

 

Off

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Current

 

Amps

5

 

310

 

 

 

 

 

 

 

Pulse Frequency

 

Hz

 

0.20

2500

 

 

 

 

 

 

 

Background Current

 

%Amps

5%

 

95%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% Peak Time

 

%

 

5

 

95

 

 

 

 

 

 

 

Postflow

 

Sec

 

0

 

60

 

 

 

 

 

 

 

AC Frequency

 

Hz

 

20

 

200

 

 

 

 

 

 

 

AC Balance

 

% EN

35

 

85

 

 

 

 

 

 

 

Hot Start

 

%

 

0

 

500

 

 

 

 

 

 

 

Arc Force

 

%

 

0

 

500

 

 

V310-T AC/DC TIG

Page 22
Image 22
Lincoln Electric IM958 manual Welding Parameters, Symbol Unit Min Max